Parallel I/O connection
144
ZW User's Manual
Setting Operation at Judgment Output
Set the hysteresis width of the judgment upper/lower limit values and judgment output timing.
3-6 Setting Threshold Value p.64
Item
Setting item
Setting value
Description
Judgment
output
Hysteresis width
0 to 99.9999mm
Sets the hysteresis value (difference between operating point and
recovery point) of the judgment upper/lower limit values when HIGH/
PASS/LOW judgment is unstable near the boundary.
Timer mode
OFF (default value)
Outputs the judgment as soon as the judgment result has been applied.
Off Delay
Delays the falling edge of the PASS output by the value set at [Timer
Duration] after the judgment result has been applied.
On Delay
Delays the rising edge of the PASS output by the value set at [Timer
Duration] after the judgment result has been applied.
O
N
OFF
O
N
OFF
O
N
OFF
HIGH threshold
v
al
u
e
Meas
u
red
v
al
u
e
LO
W
threshold
v
al
u
e
HIGH o
u
tp
u
t
PASS o
u
tp
u
t
LO
W
o
u
tp
u
t
Hysteresis
(hysteresis
w
idth)
Action point
Ret
u
rn point
HIGH threshold
v
al
u
e
Meas
u
red
v
al
u
e
LO
W
threshold
v
al
u
e
O
N
OFF
O
N
OFF
O
N
OFF
HIGH o
u
tp
u
t
PASS o
u
tp
u
t
LO
W
o
u
tp
u
t
HIGH threshold
v
al
u
e
Meas
u
red
v
al
u
e
LO
W
threshold
v
al
u
e
O
N
OFF
O
N
OFF
O
N
OFF
HIGH o
u
tp
u
t
PASS o
u
tp
u
t
LO
W
o
u
tp
u
t
: Timer time
HIGH threshold
v
al
u
e
Meas
u
red
v
al
u
e
LO
W
threshold
v
al
u
e
O
N
OFF
O
N
OFF
O
N
OFF
HIGH o
u
tp
u
t
PASS o
u
tp
u
t
LO
W
o
u
tp
u
t
: Timer time
Содержание ZW-C1*T
Страница 17: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 16 1 2 Basic Operation Flow 17 ...
Страница 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Страница 116: ...Setting the System 114 ZW User s Manual MEMO ...
Страница 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Страница 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Страница 319: ...Index ZW User s Manual 317 Index 11 ...
Страница 321: ......