Parallel I/O connection
138
ZW User's Manual
Settings for Analog Output
The following describes the settings for outputting the current measurement results from the analog output of
the 20-pole terminal block.
Setting the analog output destination
With analog output, the measurement results can be output converted to a current from 4 to 20 mA or a voltage
from -10 to +10 V.
Selects which to output, the current or the voltage.
The same output destination is set for all banks. The output destination cannot be set separately for individual banks.
Explorer pane
: [Device Group] | [(Sensor Name)] | [System]
[System Data] (double-click)
Edit pane
: [Sensor settings] icon (
)
Item
Setting item
Setting value
Description
Sensor settings
Analog output
Voltage output
(default value)
Voltage output
Current output
Current output
1
Set the operating mode to the FUN mode.
3-3 Switching operation modes p.57
2
Select the output destination from [Analog
output].
The analog output destination can also be set with key operations on the Sensor Controller.
Setting the analog output destination p.264
Important
Note
Содержание ZW-C1*T
Страница 17: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 16 1 2 Basic Operation Flow 17 ...
Страница 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Страница 116: ...Setting the System 114 ZW User s Manual MEMO ...
Страница 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Страница 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Страница 319: ...Index ZW User s Manual 317 Index 11 ...
Страница 321: ......