Details Displayed on the Sub-display
The items listed in the following table appears on the sub-display.
Press the
/
keys to toggle the display.
Display Details
Description
Threshold
Displays the HIGH and LOW threshold values for tasks for displayed target.
THRESHOLD-H indicator lights for the HIGH threshold value. THRESHOLD-L indicator lights for the LOW
threshold value.
Analog output
Displays the voltage or current value output in analog format.
The display details for the output destination setting are different for voltage output and for current output.
(Values displayed here are reference values only. These values differ from actual analog output values.)
Judgment result
The judgment result for each task appears.
The TASK1, 2, 3 and 4 judgment results are displayed starting from the left.
H: HIGH
P: PASS
L: LOW
E: ERROR
Resolution
Displays the fluctuation width (peak to peak) of the measured value over a fixed amount of time.
Exposure time
Displays the current exposure time.
The time is displayed in the range 1 to 5000
s.
Distance
Displays the distance from the Sensor Head to a target to measure.
Effective bank
Displays the current bank number.
Displayed task
Displays the currently selected task number from TASK1 to TASK4.
The measured value for the selected task appears on the main display.
Ethernet communication
status
Whether Ethernet communications are possible is displayed.
ONLINE: Communication possible
OFLINE: Communication not possible
Ethernet link status
Whether the Ethernet connection is enabled is displayed.
LINK.OK: Connection established
LINK.--: Connection not established
Tag link status
The status of EtherNet/IP tag link communication is displayed.
TAG.INI: Initializing
TAG.OK: Tag connection established
TAG.--: Tag connection not established
TAG.ER1: Tag link abnormality
TAG.ER2: Other abnormality
Internal logging status
Displays the status of operation internal logging.
LOG.RDY : Internal logging stopped state (When ZW start, When internal logging data is cleared, When
internal logging stopped)
LOG.RUN : Internal logging in progress
LOG.END : Internal logging ended state(When internal logging is automatically ended)
Содержание ZW-C1*AT
Страница 17: ...ZW User s Manual 1 15 ...
Страница 19: ...1 Basic configuration Basic configuration 1 1 ZW series Displacement Sensors 18 1 2 Basic Operation Flow 19 ...
Страница 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Страница 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Страница 120: ...Setting the System 118 ZW User s Manual MEMO ...
Страница 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Страница 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Страница 270: ...Offline Debugging of the Sensor Control Program and Sensor Operation 268 ZW User s Manual MEMO ...
Страница 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Страница 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Страница 449: ......