No-protocol Connection
244
ZW User's Manual
Zero reset cancel command <ZC command>
Cancel the zero reset of the specified task.
<Command format>
<Response format>
Normal processing
• If the task number is omitted, the zero reset is canceled for the task of which the result is currently displayed.
• If "4" is set for the task number, the zero reset is canceled for all tasks.
When a command was not successfully processed
<Parameter explanation>
Parameter
Description
Task number
Specifies the number of the task for which the zero reset is to be cancelled.
0: TASK1
1: TASK2
2: TASK3
3: TASK4
4: TASK1 to 4
CR
C
Z
↑
Task n
u
m
b
er
↑
Space
O
K
CR
E
R
CR