![Omron ZW-7000 Series Скачать руководство пользователя страница 119](http://html1.mh-extra.com/html/omron/zw-7000-series/zw-7000-series_user-manual_742279119.webp)
Performing internal logging
ZW-8000/7000/5000
User's Manual
117
3
Opera
tio
n durin
g RUN Mo
de
Performing Internal Logging with Parallel I/O
The logging start and end timings can be specified using LOGGING input signals from parallel I/O. When doing
so, follow the procedure below to set the data logging conditions.
Multi view Explore
: [System] (double-click)
→
Edit pane
: [Sensor Settings] icon (
)
→
Sensor settings window
: [Internal logging setting]
1
Set the logging conditions for internal logging.
There are three settings: Number of logging, number of logging decimation, and overwrite mode.
LOGERR signal is turned ON at the following cases:
• Overwrite mode is OFF
• 2,000,000 items have already been logged in the internal memory at the beginning of logging.
To continue to log regardless of the logging count while LOGGING input signal is turned ON, set as
below:
• Number of logging data: 0
• Overwrite mode: ON
When the number of loggings reaches 2,000,000, past logging data is overwritten and logging continues
on the latest data.
Overwrite mode and label insert mode cannot be used at the same time.
2
Set the output conditions of internal logging data.
Set the conditions for the external output using the non-procedural command LO.
Item
Setting item
Setting value
Description
Internal logging
setting
Number of
logging data
0 to 2000000
(default value: 100000)
Set the number of data to save for each internal logging
output data.
Internal logging
settings
0 to 1000
(default value: 1)
Set the interval of saving internal logging data.
If 1 is set, all data is saved. If 2 is set, one measured data is
saved every two measurements.
If 0 is set, data is saved only when the hold value is applied.
Overwrite mode
OFF (default value)/ON
Set whether to make the internal logging mode run in
overwrite mode.
Sets the operation to be performed when the logging count
exceeds the set number of logging data.
OFF: Internal logging is stopped.
ON: The oldest logging data is overwritten.
Label insert
mode
OFF (default value)/ON
Set the operation to be performed when logging input is
turned on.
OFF: No operation.
ON: When logging input is turned on, inserts label into log-
ging data.
Item
Setting item
Setting value
Description
Internal logging
setting
Output data
format
ASCII (default value)/
Binary
Select the output format for outputting internal logging data.
Содержание ZW-7000 Series
Страница 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Страница 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Страница 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Страница 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 289: ...9 APPENDICES APPENDICES 9 1 Specifications and External Dimensions 288 9 2 Laser safety 323 9 3 Firmware Update 324 ...
Страница 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Страница 335: ......