15
ZJ-SD
User’s Manual
S
ect
io
n
2
P
R
E
P
ARA
T
IO
N
FO
R
ME
ASUR
EM
ENT
Section 2
Installing Sensor Heads
Installing Sensor Heads
This section describes how to install Sensor Heads.
Sensor Head
■
Installation
1.
Fix the Sensor Head using screws.
The screws must be tightened with a torque of 0.5 Nm or less.
• Mount the Sensor Head in a stable location with little vibration.
• When this sensor is used and installed in combination with a distance sensor, we recommend
using the exclusive mounting bracket (ZJ-XBU1).
• Do not allow anything to touch the metal case of the Sensor Head. Failure to do so might prevent
accurate measurement by the sensor.
Setting the Installation Distance
2.
Adjust the angle of the Sensor Head.
Loosen the two screws on the sides of the holder, and adjust the angle of the Sensor Head so that it faces
the object to be measured.
Do not remove the screws.
3.
Tighten the screws on the sides of the holder to set the angle.
Firmly tighten both screws to a maximum torque of 0.5 N·m.
Preamplifier
Sensor Head
Connector