Timing Charts
56
ZG2-DSU User’s Manual
Timing Charts
This section explains the timing charts of the I/O signals that are exchanged between the
Data Storage Unit and external devices.
Logging
Process
Description
(1) Logging
Data that matches preset conditions is logged to internal memory
on the Data Storage Unit.
(2) Logging cycle
The measurement cycle of the Sensor Controller is the logging
cycle.
(3) Copy to Memory
Card
Logged data is automatically copied to the Memory Card after
logging ends.
Approximate copying times are as follows:
•Profiles: Approx. 250 ms x number of profiles
•Measurement values: Approx. 400 ms + (7ms x number of
profiles)
(4) Process executing
The BUSY signal turns ON while the Data Storage Unit is executing
processing. New operation instructions cannot be accepted while
the BUSY signal is ON.
START signal or
↑
key
STOP signal
or
↓
key
BUSY signal
OFF
ON
OFF
ON
OFF
ON
(3)
Copy to
Memory Card
(1) Logging
(2) Logging cycle
(4) Process executing
Logging end
Logging start
Содержание ZG2-DSU
Страница 1: ...User s Manual Cat No Z289 E1 01 Smart Sensor Data Storage Unit ZG2 DSU ...
Страница 10: ...8 ZG2 DSU User s Manual MEMO ...
Страница 14: ...12 ZG2 DSU User s Manual MEMO ...
Страница 38: ...Loading Logging Data to an External Device 36 ZG2 DSU User s Manual MEMO ...
Страница 42: ...Transferring Bank Data to the Controller 40 ZG2 DSU User s Manual MEMO ...
Страница 52: ...Bank Functions 50 ZG2 DSU User s Manual MEMO ...
Страница 86: ...Updating the Firmware 84 ZG2 DSU User s Manual MEMO ...
Страница 89: ...6 APPENDICES INDEX 87 ZG2 DSU User s Manual MEMO ...