Switching Mode Power Supply

 ZEN-PA03024

1

Switching Mode Power Supply

ZEN-PA03024

Please read and understand this catalog before purchasing the prod-
ucts. Please consult your OMRON representative if your have any ques-
tions or comments. Refer to Warranty and Application Considerations
(page 8), and Safety Precautions (page 6)

New Compact Power Supply (30 W) for ZEN 
Programmable Relays

• Slim size with a depth of 56 mm (W 

´ 

´ 

D: 70  

´ 

90  

´ 

56 mm).

• EMI: Conforms to EN61000-6-3 (Class B).

• Allows parallel operation.

• Output voltage: 24 VDC; Output current: 1.3 A; Capacity: 30 W

• Safety standards: UL508/60950/1604, 

CSA C22.2 No. 14/60950/213,
EN60950(VDE0806), EN50178(VDE0160)

• Uses lead-free soldering.

• Six-language instruction manual provided.

Model Number Structure

Model Number Legend

1. Unit

PA: Power supply unit

2. Power Ratings

030: 30 W

3. Output voltage

24: 24 V

Ordering Information

List of Models

Accessories (Order Separately)

1

2

3

ZEN-PA 030 24

Power ratings

Input voltage

Output voltage

Output current

Model number

30 W

100 to 240 VAC

24 VDC

1.3 A

ZEN-PA03024

Name

Models

Mounting Track

50 cm (l) 

´

 7.3 mm (t)

PFP-50N

1 m (l) 

´

 7.3 mm (t)

PFP-100N

1 m (l) 

´

 16 mm (t)

PFP-100N2

End Plate

PFP-M

Spacer

PFP-S

Содержание ZEN-PA03024

Страница 1: ...lel operation Output voltage 24 VDC Output current 1 3 A Capacity 30 W Safety standards UL508 60950 1604 CSA C22 2 No 14 60950 213 EN60950 VDE0806 EN50178 VDE0160 Uses lead free soldering Six language instruction manual provided Model Number Structure Model Number Legend 1 Unit PA Power supply unit 2 Power Ratings 030 30 W 3 Output voltage 24 24 V Ordering Information List of Models Accessories Or...

Страница 2: ... note 2 105 to 135 of rated load current inverted L drop intermittent automatic reset Parallel operation Yes 2 units max For details refer to the derating curve in Engineering Data For DC input parallel operation is possible only for 110 to 350 VDC Series operation No Others Ambient temperature Operating Refer to the derating curve in Engineering Data with no icing or conden sation Storage 25 to 7...

Страница 3: ...ler V V DC OUTPUT Fuse 2A Overcurrent circuit Current detection circuit ZEN PA03024 No Name Function 1 AC input terminal L1 Connect the input line to this termi nal A fuse is included in the cir cuit 2 AC input terminal L2 N Connect the input line to this termi nal Negative pole for DC input 3 DC output terminals V Connect the load lines to these ter minals 4 DC output terminals V Connect the load...

Страница 4: ...m possible damage by overcurrent When the output current rises above 105 min of the rated current the protection function is triggered decreasing the out put voltage When the output current falls within the rated range the overload protection function is automatically cleared The values shown in the above diagrams are for reference only Note 1 Internal parts may occasionally deteriorate or be dama...

Страница 5: ...ting Holes 4 7 Sliding 13 max ZEN PA03024 4 5 15 25 25 25 25 10 10 7 3 0 15 35 0 3 27 0 15 1 4 5 15 25 25 25 25 15 10 10 1 000 27 24 16 29 2 1 1 5 50 11 5 10 6 2 1 8 1 35 5 35 3 1 8 1 3 4 8 5 16 12 44 3 16 5 10 34 8 35 0 3 Mounting Track PFP 100N PFP 50N PFP 100N2 End Plate PFP M Spacer PFP S 1 000 500 See note Note The values shown in parentheses are for the PFP 50N M4 x 8 pan head screw ...

Страница 6: ...re than 100 N force to the terminal block when tightening the terminals Be sure to remove the sheet covering the product before turning ON the Power Supply and confirm that nothing is interfering with heat dissipation Installation Environment Do not use the Power Supply in locations subject to shocks or vibrations In particular install the Power Supply as far away as possible from contactors or ot...

Страница 7: ...djust the output voltages of the Power Supplies to the same value In Case there is No Output Voltage The possible cause for no output voltage may be the presence of an overload or overvoltage condition or may be due to the functioning of a latching protective device The latching protection may operate if a large amount of surge voltage such as a lightening surge occurs while turning ON the Power S...

Страница 8: ...NTY NEGLIGENCE OR STRICT LIABILITY In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATI...

Отзывы: