Function
This command is used to check the NORM/ERR indicator lighting colors for communications results
that are set in the Reader/Writer.
Command Format
Response Formats
• Normal Response
GET OPERATION INDICATOR CUSTOM CONDITIONS
Byte-0
Byte-1
Byte-2
Byte-3
Byte-4
Byte-5
Byte-6
Byte-7
Byte-8
Byte-9
Byte-10
Byte-11
Transaction identi-
fier
Protocol identifier
Field length
Unit
identifier
Function
code
Register address
Word count
X
X
0000 hex
0006 hex
FF hex
03 hex
B800 hex
0003 hex
Parameter
Description
Default setting
Register address
The register address (B800 hex) that specifies the operation indicator custom
settings
Word count
The number of words in the operation indicator custom conditions to read (0003
hex)
Byte-0
Byte-1
Byte-2
Byte-3
Byte-4
Byte-5
Byte-6
Byte-7
Byte-8
Transaction identi-
fier
Protocol identifier
Field length
Unit
identifier
Function
code
Byte
count
X
X
0000 hex
0009 hex
FF hex
03 hex
06 hex
Byte-9
Byte-10
Byte-11
Byte-12 Byte-13 Byte-14
Color to flash once
for normal com-
mand execution
Color to flash once
for command error
Color to flash once
for unstable com-
munications
2 bytes
2 bytes
2 bytes
Parameter
Description
Byte count
The number of bytes in the operation indicator custom settings (06 hex)
Color to flash once
for normal com-
mand execution
Gives the color to flash once when V780 command processing ends nor-
mally in 4-digit hexadecimal.
0001 hex: Green
0002 hex: Red
0003 hex: Yellow
0004 hex: Blue
0004 hex: Blue
0006 hex: Magenta
0007 hex: White
FFFF hex: Do not flash.
0001 hex
Color to flash once
for command error
Gives the color to flash once when V780 command processing ends in an
error in 4-digit hexadecimal.
*The colors settings are they same as for flashing once for normal command
completion, given above.
0002 hex
Color to flash once
for unstable com-
munications
Gives the color to flash once when the results of executing communications
diagnostics indicates that communications are unstable in 4-digit hexadeci-
mal.
*The colors settings are they same as for flashing once for normal command
completion, given above.
0003 hex
Содержание V780 Series
Страница 22: ...Version Upgrade Information 20 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 60: ...3 Part Names and Functions 3 14 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 70: ...4 Installation and Connections 4 10 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 76: ...5 Preparations for Communications 5 6 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 152: ...6 Functions 6 76 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 334: ...8 Browser Interface 8 44 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 358: ...9 Troubleshooting 9 24 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 362: ...10 Maintenance and Inspection 10 4 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 392: ...Appendices A 30 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 393: ...I 1 I UHF RFID System V780 series Reader Writer User s Manual Z389 Index ...
Страница 397: ......