RFID System
User's Manual
(Modbus TCP)
Section 6
Functions
Getting Communications Diagnostic Results
1.
Use the GET COMMUNICATIONS DIAGNOSTIC INFORMATION query to get the diagnostic results.
Query Format
Response Format
Normal Response
Communications diagnostic information
Parameter
Size
Description
Operating time
4 bytes Contains the system operating time for communication diagnostic in 8-digit hexadecimal.
00000000 to FFFFFFFF hex (unit: ms)
Query type
2 bytes Contains the query type for communication diagnostic in 4-digits hexadecimal.
0001 hex : READ ID
0002 hex : READ DATA
0003 hex : WRITE DATA
0004 hex : LOCK
0005 hex : DATA FILL
0006 hex : RF TAG OVERWRITE COUNT CONTROL
0007 hex : RESTORE DATA
0008 hex : COPY DATA
Communications
result
2 bytes Contains the error code for communication diagnostic in 4-digits hexadecimal.
(This is the upper word of the end code in response to the RF Tag communications query.)
0000 hex : Normal end
0003 hex : Communications precaution
2001 hex : RF Tag missing error
2002 hex : RF Tag communications error
2003 hex : Tag ID mismatch error
2004 hex : RF Tag address error
2005 hex : RF Tag lock error
2006 hex : RF Tag verification error
2007 hex : RF Tag data lost error
2008 hex : RF Tag system error
2009 hex : RF Tag overwriting error
Diagnostic result
2 bytes Contains the result for communication diagnostic in 4-digits hexadecimal.
0000 hex : Normal communications
0001 hex : Insufficient power to send
0002 hex : Insufficient power to receive
0003 hex : Too much noise
0004 hex : Insufficient signal-to-noise ratio.
•
The value is 0000 hex (fixed) when the communications result shows normal communications.
•
If a communications precaution is given for the communications result, the result indicates the
cause.
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
Byte 10
Byte 11
Transaction
identifier
Protocol identifier
Field length
Unit
identifier
Function code
Register address
Word count
X
X
0000 hex
0006 hex
FF hex
03 hex
CA00 hex
0000 hex
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
···
Byte 36
Transaction
identifier
Protocol identifier
Field length
Unit
identifier
Function
code
Byte count
Communications diagnostic information
X
X
0000 hex
001F hex
FF hex
03 hex
1C hex
(28 bytes)
Byte 9
···
Byte 12
Byte 13
Byte 14
Byte 15
Byte 16
Byte 17
Byte 18
Byte 19
Byte 20
Byte 21
Byte 22
Byte 23
Byte 24
Byte 25
Byte 26
Byte 27
···
Byte 34
Byte 35
Byte 36
Operating time
Query type
Communications
result
Diagnostic result
Send power level
Receive power
level
Noise level
Power level
Tag ID data
(Reserved)
4 bytes
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
2 bytes
8 bytes
2 bytes
Содержание V680S Series
Страница 16: ...14 RFID System User s Manual Modbus TCP Introduction Introduction MEMO ...
Страница 58: ...56 Section 1 Data Characteristics RFID System User s Manual Modbus TCP Section 1 Product Overview MEMO ...
Страница 64: ...62 Section 2 System Configuration RFID System User s Manual Modbus TCP Section 2 System Configuration MEMO ...
Страница 72: ...70 Section 3 Component Names RFID System User s Manual Modbus TCP Section 3 Component Names MEMO ...
Страница 242: ...240 Section 8 Operation Interface RFID System User s Manual Modbus TCP Section 8 Web Browser Interface ...
Страница 337: ...Index 335 RFID System User s Manual Modbus TCP Index ...
Страница 342: ...340 RFID System User s Manual Modbus TCP MEMO ...
Страница 343: ......