24
S
ect
io
n
2
Conne
c
tin
g a
nd Re
mov
in
g
the
Ant
e
nn
a
Conne
c
tor
Heat-resistive RFID System
User's Manual
Section 2
Installation, Connections, and Wiring
Connecting and Removing the Antenna Connector
A single Antenna can be connected to the Controller. A V700-A40-W Antenna Cable (order separately) is
normally required to connect the Antenna. Cables with a length of up to 30 m are available.
Connecting and Removing the Connector
• Connecting
1.
Hold the connector cable locking section, and insert
matching the black mark on the Controller with the white
mark on the connector.
2.
Push the connector in vertically until it locks.
Be sure to grip the cable locking section. The connector will
not lock if only the ring section is pushed.
• Removing
1.
Grip the ring section and pull the connector out verti-
cally.
The cable cannot be removed if the cable locking section is
gripped.
Never pull excessively on the cable. Doing so will cause bro-
ken wires and damage.
Do not remove or connect the connector when the power is
turned ON. Doing so will cause a malfunction.
Cable locking section
Ring section