98
SECTION
5
Adjust
ing the
Imag
e (Image
Ad
jus
t)
V530-R160
Operation Manual
SECTION 5
Setting Reading Conditions
BGS Levels
This function suppresses the object's background to stabilize reading, eliminating noise and
other disturbances.
Set the upper and lower limits of the BGS density while monitoring the image.
Densities lower than the set lower limit will be converted to 0 (i.e., areas with densities lower than
that value will not be read), densities higher than the set upper limit will be converted to 255, and
intermediate densities will be graded between 0 and 255. In other words, only the areas with den-
sities between the set lower and upper limits will be read.
Example: Lower limit set to 150 and upper limit set to 220
1.
Select
0. Image Adjust/BGS levels
.
Background density
Lower limit: 150
Read density
Upper limit: 220
0
255
Background
Reading
object
Image areas with densities of
149 or lower will not be read
and the density will be changed to 0.
Only image areas with densities
between 150 and 220 will be read.
The whole image is graded from 0
to 255.
Содержание V530-R160E
Страница 36: ...34 SECTION 1 Operational Flow V530 R160 Operation Manual SECTION 1 Outline MEMO...
Страница 144: ...142 SECTION 5 Setting Reading Conditions QRCode V530 R160 Operation Manual SECTION 5 Setting Reading Conditions MEMO...
Страница 192: ...190 SECTION 7 Checking the Version Version V530 R160 Operation Manual SECTION 7 System Settings MEMO...
Страница 250: ...248 SECTION 8 Serial Interface Host Link V530 R160 Operation Manual SECTION 8 Communication with the Host MEMO...
Страница 288: ...286 SECTION 10 Glossary SECTION 10 V530 R160 Operation Manual SECTION 10 Appendix MEMO...