3-6
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
ACK/NAK Options
ACK/NAK Options
RES-NAK Defaults
The following are general outlines of the
ACK/NAK
protocol. Items that are framed by
brackets (
[ ]
) can either be disabled or enabled. LRC does not include STX, but it does
include preamble, postamble, and ETX.
Symbol Data Output
TX to host:
[STX] [preamble] SYMBOL DATA [postamble] [ETX] [LRC]
Response from host:
ACK/NAK. Sent when LRC, ETX, postamble, or timeout (waiting
for more data) are detected (if REQ is disabled) depending on what is enabled.
Commands from Host to Reader
TX to Reader:
[STX] <command> [ETX] [LRC]
Response from Reader:
ACK/NAK. Sent when LRC, ETX, or command-ending angle
bracket ‘
>
’ are received, depending on what is enabled.
Command Response from Reader to Host
TX to host:
[STX] [preamble] COMMAND RESPONSE DATA [postamble] [ETX] [LRC]
Response from host:
ACK/NAK. Sent when LRC, ETX, postamble, command-ending
angle bracket ‘
>
’, or timeout (waiting for more data) are detected, depending on what is
enabled.
As with
Polling Mode
<K140,5>
, the reader can optionally perform the REQ and RES event
sequences in ACK/NAK mode. If the sender does not receive an ACK or NAK, it will send
REQ to request such a response (if enabled). When the sender receives an ACK, too many
NAKs, or times out (if already enabled), it will send a RES (if enabled) to terminate the trans-
action.
Note:
See
ACK/NAK Data Flow Examples
for sample ACK/NAK communication scenarios.
Definition:
These parameters take effect for
ACK/NAK
<K140,4>
on the main RS-232
port and are completely independent of the
Polling Mode Options
<K148>
.
The reader always follows the protocol in both directions (to and from the
host). There is no option to disable it from either direction.
Serial Cmd:
<
K147,
RES,REQ,STX,ETX,ACK,NAK
>
RES: (Reset)
00 (disabled)
REQ: (Request)
00 (disabled)
STX: (Start of Text)
00 (disabled)
ETX: (End of Text)
00 (disabled)
ACK: (Acknowledge)
06
NAK: (Negative Acknowledge)
15
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...