Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
7-63
I/O Parameters
EZ Trax Output
Transfer Port
Image Mode
Good Read
Outputs the first Good Read image in the read cycle. The image file will immediately follow
the symbol data.
Usage:
Useful for when you want to configure EZ Trax output using serial commands
instead of the EZ Trax graphic interface.
Definition:
When EZ Trax output is enabled, the imager will attempt to output all
enabled EZ Trax options. EZ Trax will not function unless enabled.
Serial Cmd:
<
status
,transfer port,image mode,image format,image quality,object info
enable,grade enable
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Definition:
Selects the communication port that will be used to transfer image files.
Serial Cmd:
<
K757,
status
,
transfer port
,image mode,image format,JPEG quality,object
info enable,grade enable
>
Default:
RS-232
Options:
0 = RS-232
3 = Ethernet TCP Port 1
4 = Ethernet TCP Port 2
Definition:
Determines which read cycle condition triggers image file output.
Serial Cmd:
<
K757,
status,transfer port,
image mode
,image format,image quality,object
info enable,grade enable
>
Default:
Disabled
Options:
0 = Disabled
1 = Good Read
2 = No Read
3 = No Read and Good Read
4 = Mismatch
Содержание V430-F-series
Страница 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Страница 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Страница 97: ...4 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 Additional Notes about Calibration ...
Страница 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Страница 265: ...8 30 Auto Focus Multi Code Reader V430 series User s Manual Z392 ISO IEC 29158 Symbol Quality Output ...
Страница 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Страница 325: ...11 18 Auto Focus Multi Code Reader V430 series User s Manual Z392 Request All Configuration Database Settings ...
Страница 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...