3-9
3 System-defined Variables Related to the Built-in EtherNet/IP Port
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
3-2 Syst
em-
d
efi
n
ed
V
ariab
les
3
Meanings of Error Status Bits
Note
Bits 14 and 15 are never TRUE for the built-in EtherNet/IP port.
Precautions for Correct Use
Precautions for Correct Use
Do not use
_ErrSta
(Controller Error Status) in the user program. There may be a delay in updat-
ing them and concurrency problems may occur with function module error status. Use this vari-
able only to access status through communications from an external device.
Functional Classification: EtherNet/IP Communications Status
You can check the status of the built-in EtherNet/IP port (e.g., communications status).
Bit
Meaning
15
Reserved)
14
Collective slave error status: This bit indicates if a Controller error was detected for levels (e.g., a Unit, slave,
axis, or axes group) that are lower than the event source (i.e., for a function module).
TRUE: A Controller error has occurred at a lower level.
FALSE: A Controller error has not occurred at a lower level.
(Valid for
_MC_ErrSta,
and
_EC_ErrSta
.)
8 to 13
Reserved.
7
This bit indicates whether a major fault level Controller error has occurred.
TRUE: A major fault level Controller error has occurred.
FALSE: A major fault level Controller error has not occurred.
6
This bit indicates whether a partial fault level Controller error has occurred.
TRUE: A partial fault level Controller error has occurred.
FALSE: A partial fault level Controller error has not occurred.
5
This bit indicates whether a minor fault level Controller error has occurred.
TRUE: A minor fault level Controller error has occurred.
FALSE: A minor fault level Controller error has not occurred.
4
This bit indicates whether an observation level Controller error has occurred.
TRUE: An observation level Controller error has occurred.
FALSE: An observation level Controller error has not occurred.
0 to 3
Reserved.
Variable name
Meaning
Function
Data type
Range of
values
Reference
_EIP_EtnOnlineSta
Online
NY-series Controller: Indicates that the
built-in EtherNet/IP port’s communications
can be used via the communications port
1 (that is, the link is ON, IP address is
defined, and there are no errors).
TRUE: The built-in EtherNet/IP port’s
communications can be used.
FALSE: The built-in EtherNet/IP port’s
communications is disabled due
to an error in initial processing,
restart processing, or link OFF
status.
BOOL
TRUE or
FALSE
WORD
15
Bit:
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Содержание Sysmac NY512-1300
Страница 290: ...9 Socket Service 9 32 NY series Industrial Panel PC Industrial Box PC Built in EtherNet IP Port User s Manual W563 ...
Страница 310: ...10 FTP Server 10 20 NY series Industrial Panel PC Industrial Box PC Built in EtherNet IP Port User s Manual W563 ...
Страница 324: ...11 FTP Client 11 14 NY series Industrial Panel PC Industrial Box PC Built in EtherNet IP Port User s Manual W563 ...
Страница 452: ...Appendices A 66 NY series Industrial Panel PC Industrial Box PC Built in EtherNet IP Port User s Manual W563 ...
Страница 453: ...Index 1 NY series Industrial Panel PC Industrial Box PC Built in EtherNet IP Port User s Manual W563 I Index ...
Страница 459: ......