![Omron Sysmac NY512-1300 Скачать руководство пользователя страница 182](http://html.mh-extra.com/html/omron/sysmac-ny512-1300/sysmac-ny512-1300_user-manual_742451182.webp)
7 Tag Data Link Functions
7-66
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
Additional Information
You can also execute the Reset service of the Identity object for the Controller to clear the tag
data link settings. The procedures to execute the service from the Network Configurator is given
below.
(1) Connect the Network Configurator to the network.
(2) Select
Tool - Setup Parameters
on the main window.
Then the dialog box for the general parameter settings are displayed.
(3) Specify the target device and message to send.
•
Target Node Address: Enter the IP address of the target device.
•
Service:
Select
Reset
.
•
Class:
Enter
01
.
•
Instance:
Enter
01
.
•
Attribute:
Enter
00
.
•
Data:
Enter
02
.
(4) Click the
Send
Button.
You can save device parameters set in the Network Configurator or device parameters uploaded from
the network in a network configuration file.
1
Select
File - Save As
.
The following dialog box is displayed.
Untitled.nvf is displayed as the default file name.
7-2-14 Saving the Network Configuration File
Содержание Sysmac NY512-1300
Страница 290: ...9 Socket Service 9 32 NY series Industrial Panel PC Industrial Box PC Built in EtherNet IP Port User s Manual W563 ...
Страница 310: ...10 FTP Server 10 20 NY series Industrial Panel PC Industrial Box PC Built in EtherNet IP Port User s Manual W563 ...
Страница 324: ...11 FTP Client 11 14 NY series Industrial Panel PC Industrial Box PC Built in EtherNet IP Port User s Manual W563 ...
Страница 452: ...Appendices A 66 NY series Industrial Panel PC Industrial Box PC Built in EtherNet IP Port User s Manual W563 ...
Страница 453: ...Index 1 NY series Industrial Panel PC Industrial Box PC Built in EtherNet IP Port User s Manual W563 I Index ...
Страница 459: ......