729
Hayes Modem AT Command Protocol
Appendix Q
Modem Settings
When this protocol is used, it is required that the modem connected to the Serial Communications Unit/Board
be initialized to the following conditions:
Note
1.
It is recommended that, in addition to the above settings, the abort timer should be set so that com-
munications are cut off if a communications error happened due to incidents such as cable discon-
nection between the Serial Communications Unit/Board and modem. The abort timer is set to 10
minutes for the modem initialization (specialized) (Sequences No. 560, No. 570, No. 580:
Initialize
Modem (Specialized)). Refer to modem’s manual for further information about abort timers.
2.
The data format of the modem (baud rate, data length, parity, stop bit) is set by AT commands issued
from a device connected to the modem. Its settings should conform to communications conditions of
the device which issues AT commands. Therefore when communications are made between the mo-
dem and Serial Communications Unit/Board, it is required that communications conditions should be
set by issuing AT commands from the Serial Communications Unit/Board.
3.
Modem settings become invalid if the power supply is turned off and must be set again. However, a
memory backup function can be used to protect settings so that even after the power supply to the
modem is turned off, it can communicate with the previous setting conditions.
For Initialize Modem (specialized), the modem initialization command is built in as message data. However, for
Initialize Modem (general-purpose), the command must be specified in the send data for PMCR(260).
Setting Example for Modem Initialization Command
• MD24FB10V Using Sequence #550 (OMRON)
The following command is set in the words specified by the 3rd operand of PMCR(260).
ATE0V0X4\V2\N3%C0*C0\X1&M0S26=10
Note
Turn ON pin 4 of DIP switches SW3 on for this Modem (ER signal always ON).
Command echo
No
Result code display format
Numeric format
Speed display, busy/dialling tone detection at connec-
tion
Baud rate display enabled, busy and dialling tone
detection enabled.
Error correction data compression display
Error correction/data compression display enabled
MNP setting
Error correction provided (auto-reliable mode)
MNP class setting
MNP class 4
V.42 compression, Error correction
Not enabled
Flow control between terminal modems
Not enabled
ER signal control
Always ON
Escape code
+
OPR 1
(Communications port settings)
OPR 2
#0226 (Sequence No. 550)
OPR 3
Address for first word containing initialization command character
string S
OPR 4
None (Set #0000)
S+0
Number of words from address set for operand 2 to end of data
4 digits Hex
S+1
Number of bytes for send data (initialization command)
4 digits Hex
S+2
:
S+n
Send data (initialization command)
(Fill data to left for odd numbers of bytes)
ASCII
Character string length of modem initialization command (bytes)
Code length of PMCR(260) when it is used (words)
A T E 0 V 0 X 4 \ V 2 \ N 3 % C 0 * C 0 \ X 1 & M 0 S 2 6 = 1 0
0020
0012
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...