K3T
@
Intelligent Signal Processor Protocol
Appendix L
Receive Data Word Allocation (4th Operand of PMCR(260))
Read Set Value HH (Continuous Units) (Sequence No. 318 (Hex
013E))
This sequence reads set value HH for continuous units.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
This sequence is similar to sequence No. 317 (Read Set Value (by Unit Number)).
Read Set Value H (Continuous Units) (Sequence No. 319 (Hex
013F))
This sequence reads set value H for continuous units. The word allocation is identical to that of sequence No.
318 (Read Set Value HH (Continuous Units)).
•
•
•
+64 to
+65
Operand
(ASCII 2 characters)
Same as above
Offset
Contents (data format)
Data
+0
Number of receive data words
(4 digits Hex)
0004 to 0061 (4 to 97 decimal)
+1
End code (2 digits Hex)
00 to 22
+2 to +3 Set value
(5 digits BCD)
•
•
•
+95 to
+96
Set value
(5 digits BCD)
Same as above
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0002
+1
Number of units (4 digits Hex)
0001 to 0020 (1 to 32 decimal)
Offset
Contents (data format)
Data
End code
+0
+1
+2
+3
+94
+95
+96
Number of receive data words
Receive data
storage words
~
~
Set value
(Undefined)
Set value
Set value
(Undefined)
Set value
End code
(Undefined)
(Undefined)
00000 to 99999
Negative sign: F (5th digit in BCD)
Example
12345
+2
+3
2345
0001
Example
–1234
+2
+3
1234
000F
Number of units
+0
+1
Number of send data words
First word of
send data
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...