609
K3T
@
Intelligent Signal Processor Protocol
Appendix L
Write Set Value O5 with Bank (Continuous Units)
(Sequence No. 312 (Hex 0138))
This sequence writes set value O5 of a bank not in use for continuous units. The word allocation is identical to
that of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).
Write Set Value O4 with Bank (Continuous Units)
(Sequence No. 313 (Hex 0139))
This sequence writes set value O4 of a bank not in use for continuous units. The word allocation is identical to
that of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).
Write Set Value O3 with Bank (Continuous Units)
(Sequence No. 314 (Hex 013A))
This sequence writes set value O3 of a bank not in use for continuous units. The word allocation is identical to
that of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).
Write Set Value O2 with Bank (Continuous Units)
(Sequence No. 315 (Hex 013B))
This sequence writes set value O2 of a bank not in use for continuous units. The word allocation is identical to
that of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).
Write Set Value O1 with Bank (Continuous Units)
(Sequence No. 316 (Hex 013C))
This sequence writes set value O1 of a bank not in use for continuous units. The word allocation is identical to
that of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).
Read Set Value (by Unit Number) (Sequence No. 317 (Hex 013D))
Reads set value HH, H, L, or LL.
Send Data Word Allocation (3rd Operand of PMCR(260))
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0004 to 0042 (4 to 66 decimal)
+1
Number of units
(4 digits Hex)
0001 to 0020 (1 to 32 decimal)
+2
Relevant unit No.
(2 digits BCD)
00 to 99
+3
Operand
(ASCII 2 characters)
4848 (“HH”),
4C4C (“LL”)
4F31 (“01”)
4820 (“H”),
4C20 (“L”)
4F35 (“05”)
Relevant unit No.
(Undefined)
Number of units
+0
+1
+2
+3
+64
+65
Number of send data words
First word of
send data
~
~
Relevant unit No.
(Undefined)
Operand
Operand
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...