540
E5ZE Temperature Controller Write Protocol
Appendix I
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Write Cooling Coefficient (Sequence No. 173 (Hex 00AD))
Writes the cooling coefficients for the cooling proportional bands for heating/cooling control.
Send Data Word Allocation (3rd Operand of PMCR(260))
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
000A (0010 decimal) (fixed)
+1
Unit No. (2 digits Hex)
00 to 0F
+2
Channel 0
Dead band/overlap band
(4 digits BCD)
0000 to 0999
+3 Channel
1
Dead band/overlap band
(4 digits BCD)
0000 to 0999
+4
Channel 2
Dead band/overlap band
(4 digits BCD)
0000 to 0999
•
•
•
+8
Channel 6
Dead band/overlap band
(4 digits BCD)
0000 to 0999
+9
Channel 7
Dead band/overlap band
(4 digits BCD)
0000 to 0999
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
000A (0010 decimal) (fixed)
+1
Unit No. (2 digits Hex)
00 to 0F
+2
Channel 0
Cooling coefficient (4 digits BCD)
0000 to 0100
+3 Channel
1
Cooling coefficient (4 digits BCD)
0000 to 0100
+4
Channel 2
Cooling coefficient (4 digits BCD)
0000 to 0100
•
•
•
+8
Channel 6
Cooling coefficient (4 digits BCD)
0000 to 0100
+9
Channel 7
Cooling coefficient (4 digits BCD)
0000 to 0100
First word of
send data
Number of send data words
+0
+1
+2
+3
+4
+5
+6
+7
+8
+9
(Undefined)
Unit No.
Cooling coefficient
Cooling coefficient
Channel 0
Channel 1
Cooling coefficient
Channel 2
Cooling coefficient
Channel 3
Cooling coefficient
Channel 4
Cooling coefficient
Channel 5
Cooling coefficient
Channel 6
Cooling coefficient
Channel 7
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...