Appendix I
E5ZE Temperature Controller Write Protocol
The E5ZE Temperature Controller Write Protocol writes and controls various settings in remote mode for the
Temperature Controller connected via a RS-232C or RS-422/485 cable from the PLC via the Serial Communi-
cations Unit/Board.
Note
1.
Negative values cannot be written. All values must be set as unsigned BCD.
2.
All sequences in this appendix operate on memory bank 0 and cannot be used for other memory
banks.
Structure of the Protocol
The following table shows the structure of the E5ZE Temperature Controller Write Protocol.
Se-
quence
No.
Communications sequence name
Function
Ladder interface
Send
word
allocation
Receive
word
allocation
150
(0096)
Write set point (setting unit 1)
Writes the set points using a setting unit of 1.
Yes
No
151
(0097)
Write set point (setting unit 0.1)
Writes the set points using a setting unit of
0.1.
Yes
No
152
(0098)
Write proportional band, integral time,
and derivative time
Writes the proportional bands, integral times,
and derivative times.
Yes
No
153
(0099)
Write control period
Writes the control periods.
Yes
No
154
(009A)
Write output mode
Writes the output modes.
Yes
No
155
(009B)
Write alarm mode
Writes the alarm modes.
Yes
No
156
(009C)
Write alarm temperature (setting unit
1)
Writes the alarm temperatures using a setting
unit of 1.
Yes
No
157
(009D)
Write alarm temperature (setting unit
0.1)
Writes the alarm temperatures using a setting
unit of 0.1.
Yes
No
158
(009E)
Write hysteresis
Writes the hysteresis.
Yes
No
159
(009F)
Start autotuning
Starts autotuning.
Yes
No
160
(00A0)
Cancel autotuning
Cancels autotuning.
Yes
No
161
(00A1)
Write setting unit
Writes the setting units.
Yes
No
162
(00A2)
Write input shift value
Writes the input shift values.
Yes
No
163
(00A3)
Write manual reset value
Writes the manual reset values.
Yes
No
164
(00A4)
Write ramp value
Writes the ramp values.
Yes
No
165
(00A5)
Write manual output value
Writes the manual output values.
Yes
No
166
(00A6)
Write output value limit
Writes the output value limits.
Yes
No
167
(00A7)
Write output value change rate limit
Write output value change rate limits.
Yes
No
168
(00A8)
Save settings
Saves settings.
Yes
No
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...