E5ZE Temperature Controller Read Protocol
Appendix H
Read Alarm Temperatures (Sequence No. 108 (Hex 006C))
Reads the alarm temperatures and stores the results in the specified words.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
`
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0002 (fixed)
+1
Unit No. (2 digits Hex)
00 to 0F
Offset
Contents (data format)
Data
+0
Number of receive data words
(4 digits Hex)
0021 (0033 decimal)
+1
Channel 0
Alarm 1 set value (rightmost 4 digits)
(4 digits BCD)
0000 to 9999
F indicates a negative number.
+2 Channel
0
Alarm 1 set value (leftmost 1 digit)
(4 digits BCD)
0000 to 0009
F indicates a negative number.
+3
Channel 0
Alarm 2 set value (rightmost 4 digits)
(4 digits BCD)
0000 to 9999
F indicates a negative number.
+4
Channel 0
Alarm 2 set value (leftmost 1 digit)
(4 digits BCD)
0000 to 0009
F indicates a negative number.
•
•
•
+29
Channel 7
Alarm 1 set value (rightmost 4 digits)
(4 digits BCD)
0000 to 9999
F indicates a negative number.
+30
Channel 7
Alarm 1 set value (leftmost 1 digit)
(4 digits BCD)
0000 to 0009
F indicates a negative number.
+31
Channel 7
Alarm 2 set value (rightmost 4 digits)
(4 digits BCD)
0000 to 9999
F indicates a negative number.
+32
Channel 07
Alarm 2 set value (leftmost 1 digit)
(4 digits BCD)
0000 to 0009
F indicates a negative number.
First word of
send data
Number of send data words
+0
+1
(Undefined)
Unit No.
Receive data
storage words
Number of receive data words
+0
+1
+2
+3
+4
+29
+30
+31
+32
Alarm 1 set value (rightmost 4 digits)
~
~
Alarm 1 set value (leftmost 1 digit)
Alarm 1 set value (rightmost 4 digits)
Alarm 1 set value (rightmost 1 digit)
Channel 0
Channel 7
Alarm 2 set value (rightmost 4 digits)
Alarm 2 set value (leftmost 1 digit)
Alarm 2 set value (rightmost 4 digits)
Alarm 2 set value (leftmost 1 digit)
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...