![Omron SYSDRIVE 3G3MX-A2002 Скачать руководство пользователя страница 139](http://html1.mh-extra.com/html/omron/sysdrive-3g3mx-a2002/sysdrive-3g3mx-a2002_user-manual_742838139.webp)
4-48
4-2 Function Mode
4
Func
tions
Reset
This function resets an Inverter trip.
• You can also reset an Inverter trip by pressing the STOP/RESET key on the Digital Operator.
• In reset selection C102, you can select alarm reset timing and either enable/disable in normal
operation.
• For the RS terminal, only NO contact is available.
Thermistor Trip Function
This function protects the motor by tripping with the built-in thermistor detecting a temperature rise.
• Allocate 19 (PTC) to multi-function input 5 (C005). This cannot be used with other multi-function
inputs. (Use a thermistor with the PTC characteristics.)
• Trip level is fixed at 3 k
Ω
±10% max. For how to connect the thermistor, refer to "Functions of the
Control Circuit Terminals" (page 2-26).
Data
Symbol
Function name
Status
Description
18
RS
Reset
ON
Shuts off the power if the Inverter is running.
Cleared at trip.
(The same process as when the power is turned on)
OFF
Same as above.
Available input terminals
C001, C002, C003, C004, C005, C006
Required settings
C102
Parameter No.
Function name
Data
Description
C102
Reset selection
00
Trip reset at power-on (example 1)
Enabled during normal operation (shuts off output)
01
Trip reset at power-off (example 2)
Enabled during normal operation (shuts off output)
02
Trip reset at power-on (example 1)
Disabled during normal operation (trip reset only)
(Example 1)
RS
Alarm
ON
OFF
ON
OFF
(Example 2)
RS
Alarm
ON
OFF
ON
OFF
Data
Symbol
Function name
Status
Description
19
PTC
Thermistor input
Connected
When the thermistor is connected between terminals S5
and SC, the Inverter can detect motor temperature and,
if the temperature exceeds the specified level, trips to
shut off the output (E35). The level is fixed.
Open
If the thermistor is not connected, the Inverter trips (E35)
to shut off the output even with this function selected.
Available input terminals
C006 only
Содержание SYSDRIVE 3G3MX-A2002
Страница 1: ...Cat No I559 E1 01 USER S MANUAL SYSDRIVE MXSERIES Multi function Compact Inverter...
Страница 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 3...
Страница 24: ......
Страница 25: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Removing and Mounting Each Part 2 5 2 3 Wiring 2 10...
Страница 90: ......
Страница 91: ...Chapter 4 Functions 4 1 Monitor Mode 4 1 4 2 Function Mode 4 5...
Страница 180: ......
Страница 181: ...Chapter 5 Maintenance Operations 5 1 Special Display List 5 1 5 2 Troubleshooting 5 5...
Страница 188: ......
Страница 189: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 6 2 Storage 6 7...
Страница 205: ...7 8 7 4 Dimensional Drawing 7 Specifications 7 4 Dimensional Drawing 3G3MX A2002 AE002 120 110 67 5 6 5 103 2 6 7 80...
Страница 208: ...7 11 7 4 Dimensional Drawing 7 Specifications 3G3MX A4004 AE007 139 2 6 7 98 118 4 130 2 5 110 5...
Страница 210: ...7 13 7 4 Dimensional Drawing 7 Specifications 3G3MX A2055 A2075 A4055 A4075 205 220 6 5 6 164 180 2 6 7 155 5 5...
Страница 212: ...7 15 7 5 Options 7 Specifications 3G3AX RBU41 95 75 2 5 208 218 5 145 35 100 5...
Страница 223: ...7 26 7 5 Options 7 Specifications 3G3AX EFI25 L3 T S R L1 L2 10 2 260 MIN 205 235 308 5 331 355 160 40 60 164 182...
Страница 230: ......
Страница 231: ...Appendix Appendix 1 Parameter List App 1 Appendix 2 Product Life Curve App 17...
Страница 249: ...INDEX...