89
Main Setup [200]
Section 11-2
Communication information
Lock Code? [218]
To prevent the keyboard being used or to change the setup of the VSD and/or
process control, the keyboard can be locked with a password. This menu,
Lock Code [218], is used to lock and unlock the keyboard. Enter the password
“291” to lock/unlock the keyboard operation. If the keyboard is not locked
(default) the selection “Lock Code?” will appear. If the keyboard is already
locked, the selection “Unlock Code?” will appear.
When the keyboard is locked, parameters can be viewed but not changed.
The reference value can be changed and the VSD can be started, stopped
and reversed if these functions are set to be controlled from the keyboard.
Overall limitation of motor rotation direction
This function limits the overall rotation, either to left or right or both directions.
This limit is prior to all other selections, e.g.: if the rotation is limited to right, a
Run-Left command will be ignored. To define left and right rotation we assume
that the motor is connected U-U, V-V and W-W.
Speed Direction and Rotation
The speed direction can be controlled by:
•
RunR/RunL commands on the control panel.
•
RunR/RunL commands on the terminal strip (terminals 1-22).
•
Via the serial interface options.
•
The parameter sets.
Fig. 63
Rotation
Modbus Instance no/
DeviceNet no:
43010
Profibus slot/index
168/169
EtherCAT index (hex)
4bc2 x h
Fieldbus format
UInt
Modbus format
UInt
Default:
0
Range:
0–9999
0
A
Right
Left
Содержание SX-F
Страница 2: ......
Страница 14: ...6 Table of contents...
Страница 20: ...12 Glossary Section 1 6...
Страница 32: ...24 Cabinet mounting Section 2 3...
Страница 58: ...50 Connecting options Section 5 6...
Страница 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Страница 74: ...66 EMC standards Section 8 1...
Страница 266: ...258 System Data 900 Section 11 9...
Страница 274: ...266 Maintenance Section 12 3...
Страница 284: ...276 Liquid cooling Section 13 12...