255
View Trip Log [800]
Section 11-8
All nine alarm lists contain the same type of data. For example DeviceNet
parameter 31101 in alarm list 1 contains the same data information as 31151
in alarm list 2. It is possible to read all parameters in alarm lists 2–9 by recal-
culating the DeviceNet instance number into a Profibus slot/index number.
This is done in the following way:
slot no = abs((dev instance no-1)/255)
index no = (dev instance no-1) modulo 255
dev instance no = slot index no+1
Example: We want to read out the process value out from alarm list 9. In
alarm list 1 process value has the DeviceNet instance number 31102. In
alarm list 9 it has DeviceNet instance no 31502 (see table 2 above). The cor-
responding slot/index no is then:
slot no = abs((31502-1)/255)=123
index no (modulo)= the remainder of the division above = 136, calculated as:
(31502-1)-123x255=136
11-8-3 Reset Trip Log [8A0]
Resets the content of the 10 trip memories.
Communication information
Note
After the reset the setting goes automatically back to “NO”. The message
“OK” is displayed for 2 sec.
EtherCAT index (hex)
247e-24b0
24b1-24e2
24e3-2514
2515-2546
2547-2578
2579-25aa
25ab-25dc
25dd-260e
Trip log list
2
3
4
5
6
7
8
9
Fieldbus format
Depends on parameter, see respective parameter.
Modbus format
Depends on parameter, see respective parameter.
Default:
No
No
0
Yes
1
Modbus Instance no/
DeviceNet no:
8
Profibus slot/index
0/7
EtherCAT index (hex)
2008
Fieldbus format
UInt
Modbus format
UInt
8A0 Reset Trip
Stp
No
Содержание SX-F
Страница 2: ......
Страница 14: ...6 Table of contents...
Страница 20: ...12 Glossary Section 1 6...
Страница 32: ...24 Cabinet mounting Section 2 3...
Страница 58: ...50 Connecting options Section 5 6...
Страница 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Страница 74: ...66 EMC standards Section 8 1...
Страница 266: ...258 System Data 900 Section 11 9...
Страница 274: ...266 Maintenance Section 12 3...
Страница 284: ...276 Liquid cooling Section 13 12...