114
Main Setup [200]
Section 11-2
Communication information
Communication Error Trip Type [25J]
Select the preferred way to react to a communication trip.
Communication information
Min Alarm [25K]
Delay time starts counting when the fault is gone. When the time delay has
elapsed, the alarm will be reset if the function is active.
Communication information
Off
0
Off
1–3600
1–
3600
1–3600 s
Modbus Instance no/
DeviceNet no:
43089
Profibus slot/index
168/248
EtherCAT index (hex)
4c11
Fieldbus format
Long, 1=1 s
Modbus format
EInt
Default:
Trip
Selection:
Same as menu [25B]
Modbus Instance no/
DeviceNet no:
43090
Profibus slot/index
168/249
EtherCAT index (hex)
4c12
Fieldbus format
UInt
Modbus format
UInt
Default:
Off
Off
0
Off
1–3600
1–
3600
1–3600 s
Modbus Instance no/
DeviceNet no:
43091
Profibus slot/index
168/250
EtherCAT index (hex)
4c13
Fieldbus format
Long, 1=1 s
Modbus format
EInt
Trip
A
Off
A