41
F3SJ-A
User’s Manual
Chapter
2
Mu
ting Sys
te
m
System Configuration and Functions
E
Wiring When External Device Monitoring Function Is Not Required
1.Disabling external device monitoring function by the setting tool
Or
2.The external device monitoring function is disabled by connecting auxiliary output 1 and external
device monitoring input as shown below, when auxiliary output 1 settings have not been changed
(output operation mode is "safety output information" and reverse output mode is "enabled").
Ref.: Minimum Wiring Required to Check the Operation of the F3SJ When Using the
Muting Function
(Wiring that does not use the external device monitoring function)
ޓ
* 1
K3
+24V D C
0V
K1
K2
Receiver
(Grey) Communication line (+)
(Pink) Communication line (-)
0V(Blue)
Power
supply
Shield
24V(Brown)
External device
monitoring input (Red)
Auxiliary output 1(Yellow)
Safety output 1(Green)
Safety output 2(White)
K1, K2
K3
: Relay or other device that controls
hazardous parts of the machine
: Load or PLC, etc. (for monitoring)
*1 F3SJ can operate even if K3 is not connected.
If K3 is not required, connect auxiliary output 1
to external device monitoring input only.
Open
Open
Open
A1
B1
* 1
*1
M1 * 1 * 2
+24V DC
0V
A1
: Contact by muting sensor A1
B1
: Contact by muting sensor B1
M1
: Muting lamp
Muting input 1 (White)
Muting input 2 (Red)
*1
When the muting function's operation check is not performed, it can work if this is open.
*2 Connect either the emitter or receiver to the muting lamp.
Emitter
Receiver
(Grey) Communication line (+)
(Pink) Communication line (-)
0V(Blue)
0V(Blue)
Power
supply
Shield
Shield
T
est input(Green)
Reset input(Y
ellow)
24V(Brown)
24V(Brown)
External device
monitoring input (Red)
Auxiliary output 1(Y
ellow)
Safety output 1(Green)
Safety output 2(White)
3
3
*
*
3
*
Two-wire type sensor cannot be used.