F3SJ-A
User’s Manual
What can be done by the setting tool
Setting Change
• Auxiliary Output 1
Configure in a bulk in case of a series connection. (to be written into the primary sensor only)
• Auxiliary Output 2
If F3SJ is used for a muting system, auxiliary output 2 cannot be used because it is used as muting input 2.
Muting System Wiring Diagrams p.40
Output Operation Mode (when assigned to auxiliary output and external indicator
output)
Function
Initial Setting
Available Setup Item
Setting Console
PC Tool For F3SJ
Output Operation Mode Safety Output
Information
See Output Operation Mode
3
3
Reverse Output Mode
Enabled
Enable/disable
3
3
Lighting-Up Pattern
ON
On/Blink[0.5s]/Blink[1.0s]/
Blink[2.0s]
3
3
Auxiliary Output
Diagnosis Function
Disabled
Enable/disable
3
3
Function
Initial Setting
Available Setup Item
Setting Console
PC Tool For F3SJ
Output Operation Mode Power-On Time
Information
(30,000 hours)
See table below
3
3
Reverse Output Mode
Disabled
Enable/disable
3
3
Output Operation Mode
Operational Description
(Output turns ON under following condition)
Setting
Console
PC Tool Forpc
tool for F3SJ
Safety Output Information
When safety output is ON
3
3
Light Level Diagnosis Information *
1
When F3SJ is under ON state and light intensity is within a
range from 100 to 130% of ON-threshold for 10 seconds or
longer.
3
3
Error/Lockout Information
Under error/lockout state
3
3
Muting/Override Information
Under either muting or override state
3
3
Blanking/Warning Zone Information *
2
When fixed blanking/floating blanking functions and warning
zone function are enabled
3
3
Designated Beam Output Information *
3
When designated beam is interrupted
–
3
Power-On Time Information
When power-on time exceeds power-on time threshold
3
3
Warning Zone Information *
4
When a warning zone is interrupted
3
3
Test input ON information
When test input is turned ON
3
3
Blanking Beam Incidence Information *
5
When fixed blanking or floating blanking beams are incident
3
3
Interlock Information
Under interlock state
3
3
Muting Error Information
Under muting error state
3
3
Excess Load Switch Frequency
Information
When the load switching frequency exceeds its threshold.
3
3
Information Trigger Information
Under either interlock, lockout, or muting error
–
3
Connected Sensor Individual Output
(1CH)
When safety output of 1CH under series connection is ON
3
(auxiliary
output 1 only)
3
(auxiliary
output 1 only)
Connected Sensor Individual Output
(2CH)
When safety output of 2CH under series connection is ON
3
(auxiliary
output 1 only)
3
(auxiliary
output 1 only)
Connected Sensor Individual Output
(3CH)
When safety output of 3CH under series connection is ON
3
(auxiliary
output 1 only)
3
(auxiliary
output 1 only)
Connected Sensor Individual
Output(4CH)
When safety output of 4CH under series connection is ON
3
(auxiliary
output 1 only)
3
(auxiliary
output 1 only)