227
Status Areas
Section 7-2
7-1-3
I/O Data
Counter Units and Positioning Units have both input and output data. Three
words are allocated for the Master’s Output Area as output data from the Mas-
ter to the Unit and three words are allocated for the Master’s Input Area as
input data from the Unit to the Master. Refer to
for
detailed information on the I/O data.
Input Data
Output Data
7-2
Status Areas
A Counter Unit or Positioning Unit has two status areas. The Unit’s Status
Flags are turned ON and OFF based on the threshold/monitor values set for
the functions in the Unit. A flag in the Communications Unit will be turned ON
only when the corresponding flag has been turned ON in one of the status
areas.
The Communications Unit’s Status Flag information is transmitted to the Mas-
ter. The Counter Unit’s or Positioning Unit’s status area can be read from a
Programming Device.
Action on bus idle
The action that is taken when the SmartSlice bus goes idle can be set.
The digital outputs can either be cleared or their maintain functionality.
The counter continues to operate normally.
Outputs cleared.
Last maintenance
date
The date of the last time Unit maintenance was performed is recorded.
2005/1/1
Function
Details
Default
I/O data
Details
Counter data and status data
(6 input bytes)
• Used to monitor counter data.
• Provides counter Status Flags.
I/O data
Details
Counter settings and control data
(6 output bytes)
Used to set up and control the counter.
Flags are t
u
rned ON
w
hen the corresponding
monitor val
u
e is exceeded. The flag stat
u
s can
b
e read from a Programming Device.
Slice I/O Unit
Master
Comm
u
nications Unit
When one of the I/O Unit's stat
u
s flags
goes ON, the corresponding stat
u
s flag in
the Comm
u
nications Units is t
u
rned ON.
Transmitted
to Master
Содержание SMARTSLICE GRT1-DRT
Страница 1: ...OPERATION MANUAL Cat No W455 E1 08 SmartSlice GRT1 Series Slice I O Units ...
Страница 3: ...SmartSlice GRT1 Series Slice I O Units Operation Manual Revised December 2018 ...
Страница 4: ...iv ...
Страница 6: ...vi ...
Страница 20: ...xx EC Directives 6 ...
Страница 62: ...42 Connecting Turnback Cables Section 3 3 ...
Страница 250: ...230 Maintenance Information Window Section 7 3 Maintenance Information Window ...
Страница 292: ...272 GRT1 CP1 L Positioning Unit Section 7 5 ...
Страница 300: ...280 GRT1 END End Unit Section 8 5 Dimensions 11 9 11 9 55 7 1 5 19 5 83 5 2 9 2 9 OMRON ...
Страница 322: ...302 Troubleshooting by Unit Section 9 5 ...
Страница 350: ...330 Explicit Messages Appendix A ...
Страница 354: ...334 Power Consumption and Weight Tables Appendix C ...
Страница 356: ...336 I O Current Consumption Table Appendix D ...
Страница 364: ...344 Revision History ...
Страница 365: ......