Chapter 4: Operation
4.2 Front Panel
The following figure shows a Front Panel.
1
2
5
4
3
a
b
Figure 4-2. Front Panel
Before running programs, either the optional Front Panel or user-supplied switches for High
Power ON/ OFF, MAN / AUTO, and E-Stop must be connected to the XFP connector on the
SmartController EX motion controller.
NOTE:
Safety regulations dictate the sequence of events required for the user to
enable high power. For instance, a user may be required to press the High Power
On button on the Front Panel after pressing the COMP / PWR button on the
pendant or issuing the eV+ Enable Power command. Users cannot jumper this
button input and still enable power (see your robot manual for further details).
1.
XFP connector
Connects to the XFP connector on the controller.
2.
System 5 V Power-On LED
Indicates whether or not power is connected to the Front Panel.
3.
Manual / Automatic Mode Switch
Switches between Manual and Automatic mode. In Automatic mode, executing pro-
grams control the mechanism, and the mechanism can run at full speed.
In Manual mode, the system limits mechanism speed and torque, to reduce the risk to
an operator working in the cell. It is the user's responsibility to determine if this is
allowed under local regulations. Manual mode initiates software restrictions on robot
speed, commanding no more than 250 mm/sec as required by RIA and ISO standards.
Please refer to your robot manual for further details.
11069-000 Rev. H
SmartController EX User's Guide
31