A - 3
Appendices
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
A-
1 CiA40
2 Drive Prof
ile
A
A-1
-1 Con
trolling the State
Machine of th
e Servo Drive
2
The operation to perform when the main circuit power is turned OFF while the Servo is ON can be set
using the Undervoltage Error Selection (3508 hex). 3508 hex = 0: Moves to a state where the main circuit
power supply is turned OFF and stops according to the setting of the Shutdown option code (605B hex).
3508 hex =1: Moves to an error processing state and stops according to the setting of the Fault reaction
option code (605E hex).
State is controlled by combining the bits in the Controlword (6040 hex) as shown in the following table.
*1
The state automatically moves to Operation enabled state after Servo Ready (Switched on) state.
*2
Quick stop commands are not supported. Even if a quick stop command is received, it will be ignored.
*3
Bit 7: Operation when Fault reset bit turns ON.
*4
When an error reset is executed with bit 7, set the bit back to 0 before giving the next command.
State Description
Conditions
Description
Not ready to switch on
The control circuit power supply is turned ON and initialization is being executed.
Switch on disabled
Initialization has been completed.
Servo Drive parameters can be set.
Ready to switch on
The main circuit power supply can be turned ON.
Servo Drive parameters can be set.
Switched on
The main circuit power supply is ON (Servo Ready).
Servo Drive parameters can be set.
Operation enabled
The Servo is ON.
Servo Drive parameters can be set.
Fault reaction active
There was an error in the Servo Drive and the cause is being determined.
Servo Drive parameters can be set.
Fault
There is an error in the Servo Drive.
Servo Drive parameters can be set.
Command Coding
Command
Controlword Bit
Move to
Bit 7
Bit 3
Bit 2
Bit 1
Bit 0
Fault reset
Enable
operation
Quick stop
Enable
voltage
Switch on
Shutdown
Disabled
Disabled
1
1
0
2, 6, 8
Switch on
Disabled
0
1
1
1
3
Switch on + Enable
operation
Disabled
1
1
1
1
3 + 4
*1
Disable voltage
Disabled
Disabled
Disabled
0
Disabled
7, 9, 10
Quick stop
Disabled
Disabled
0
1
Disabled
Not supported
*2
Disable operation
Disabled
0
1
1
1
5
Enable operation
Disabled
1
1
1
1
4
Fault reset
0
→
1
*3*4
Disabled
Disabled
Disabled
Disabled
15
Fault state
•
Errors are reset and the Servo Drive returns to its initialized state (Switch on disabled).
•
Check the Statusword (6041 hex) bit 7 (Warning) and reset it if an error has occurred.
State other
than Fault state
•
Check the Statusword (6041 hex) bit 7 (Warning) and reset it if an error has occurred.
•
The state will change according to command bits 0 to 3.
Содержание R88D-KN01H-ECT-L
Страница 136: ...3 Specifications 3 60 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 190: ...4 System Design 4 54 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 208: ...5 EtherCAT Communications 5 18 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 226: ...6 Basic Control Functions 6 18 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 268: ...7 Applied Functions 7 42 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 276: ...8 Safety Function 8 8 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 616: ...Appendices A 170 G5 series Linear Motors Servo Drives With Built in EtherCAT Communications...
Страница 617: ...Index 1 I G5 series Linear Motors Servo Drives With Built in EtherCAT Communications Index...
Страница 624: ......
Страница 625: ......