5-72
5-16 User Parameters
5
Ope
rati
ng Func
tions
• For Position Control Mode, use this parameter to set the judgment level for switching between gain
1 and gain 2. If the Control Gain Switch 1 Setting (Pn31) is set to 3, 5, 6, 9, or 10, Pn33 is enabled.
The unit depends on the Control Gain Switch 1 Setting (Pn31).
• For Speed Control Mode, use this parameter to set the judgment level for switching between gain
1 and gain 2. If the Control Gain Switch 1 Setting (Pn31) is set to 3 to 5. Pn33 is enabled. The unit
depends on the Control Gain Switch 1 Setting (Pn31).
• For Torque Control Mode, use this parameter to set the judgment level for switching between gain
1 and gain 2. If the Control Gain Switch 1 Setting (Pn31) is set to 3, Pn33 is enabled. The unit
depends on the Control Gain Switch 1 Setting (Pn31).
• Use this parameter to set the hysteresis width for the judgment level set in the Gain Switch 1 Level
Setting (Pn33). The unit depends on the Control Gain Switch 1 Setting (Pn31). The following
shows the definitions for the Gain Switch 1 Time (Pn32), Gain Switch 1 Level Setting (Pn33), and
Gain Switch 1 Hysteresis Setting (Pn34).
• The settings for the Gain Switch 1 Level Setting (Pn33) and the Gain Switch 1 Hysteresis Setting
(Pn34) are effective as absolute values (positive/negative).
• When switching between gain 1 and gain 2 is enabled, set the phased switching time only for
position loop gain at gain switching.
Pn33
Gain Switch 1 Level Setting
Setting range
0 to 20000
Unit
---
Default setting
600
Power OFF
→
ON
---
Pn34
Gain Switch 1 Hysteresis Setting
Setting range
0 to 20000
Unit
---
Default setting
50
Power OFF
→
ON
---
Pn35
Position Loop Gain Switching Time
Setting range
0 to 10000
Unit
×
166
μ
s
Default setting
20
Power OFF
→
ON
---
All modes
All modes
Pn33
0
Pn34
Pn32
Gain 1
Gain 2
Gain 1
Position
Pn35=
Kp1 (Pn10)
166
166
166
Kp2 (Pn18)
0
0
1
1
2
2
3
3
Kp1 (Pn10) > Kp2 (Pn18)
Example:
Bold solid line
Thin solid line
Gain 1
Gain 2
Gain 1
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......