7 Applied Functions
7 - 10
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
The allocations of the default output signals are as follows.
465E
---
Remote Output 3
Sets the output signal allocation and logic.
01
Port Selection
The function is the same as 4651-01 hex.
02
Logic Selection
The function is the same as 4651-02 hex.
465F
---
Zone Notification Output 1
Sets the output signal allocation and logic.
01
Port Selection
The function is the same as 4651-01 hex.
02
Logic Selection
The function is the same as 4651-02 hex.
4660
---
Zone Notification Output 2
Sets the output signal allocation and logic.
01
Port Selection
The function is the same as 4651-01 hex.
02
Logic Selection
The function is the same as 4651-02 hex.
4661
---
Position Command Status
Output
Sets the output signal allocation and logic.
01
Port Selection
The function is the same as 4651-01 hex.
02
Logic Selection
The function is the same as 4651-02 hex.
4662
---
Distribution Completed Out-
put
Sets the output signal allocation and logic.
01
Port Selection
The function is the same as 4651-01 hex.
02
Logic Selection
The function is the same as 4651-02 hex.
7-2-2
Default Setting
Index (hex)
Name
Default setting
Subindex 01 hex
Port Selection
Subindex 02 hex
Logic Selection
Set value
Status
Set value
Status
4650
Error Output
0
No allocation
1
Negative logic (NC
contact)
4651
Servo Ready Output
1
General Output 1
(OUT1)
0
Positive logic (NO
contact)
4652
Positioning Completion
Output 1
0
No allocation
0
Positive logic (NO
contact)
4653
Positioning Completion
Output 2
0
No allocation
0
Positive logic (NO
contact)
4654
Velocity Attainment
Detection Output
0
No allocation
0
Positive logic (NO
contact)
4655
Torque Limit Output
0
No allocation
0
Positive logic (NO
contact)
4656
Zero Speed Detection
Output
0
No allocation
0
Positive logic (NO
contact)
4657
Velocity Conformity Out-
put
0
No allocation
0
Positive logic (NO
contact)
4658
Warning Output 1
0
No allocation
0
Positive logic (NO
contact)
4659
Warning Output 2
0
No allocation
0
Positive logic (NO
contact)
465A
Velocity Limiting Output
0
No allocation
0
Positive logic (NO
contact)
465B
Error Clear Attribute Out-
put
0
No allocation
0
Positive logic (NO
contact)
465C
Remote Output 1
2
General Output 2
(OUT2)
0
Positive logic (NO
contact)
Index
(hex)
Subindex
(hex)
Name
Description
Refer-
ence
Содержание R88D-1SN01H-ECT
Страница 17: ...15 CONTENTS AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 266: ...3 Specifications 3 102 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 430: ...8 Safety Function 8 16 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 568: ...10 Operation 10 10 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 822: ...Appendices A 174 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 823: ...AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 I 1 I Index...
Страница 826: ...I 4 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 Appendices...
Страница 827: ......