9 Details on Servo Parameters
9 - 32
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
• Sets the following performance for the target velocity.
• The higher the gain is, the higher the following performance of the internal command is for the target
velocity.
• The set value is valid when
TDF Velocity Control
-
Command Following Gain Selection
(3120-10
hex) is set to 0 (use the Command Following Gain).
• Selects the command following gain switching method.
Description of Set Values
• Sets the cutoff frequency to the velocity command.
• The higher the set value is, the higher the following performance of the internal command is for the
target velocity.
• The set value is valid when
TDF Velocity Control
-
Command Following Gain Selection
(3120-10
hex) is set to 1 (use the Command Following Gain 2).
Subindex 01 hex: Command Following Gain
Subindex 10 hex: Command Following Gain Selection
Set
value
Description
0
Use the Command Following Gain.
1
Use the Command Following Gain 2.
Subindex 11 hex: Command Following Gain 2
Содержание R88D-1SN ECT Series
Страница 544: ...7 Applied Functions 7 52 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 560: ...8 Safety Function 8 16 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 700: ...10 Operation 10 10 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586...
Страница 969: ...AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 I 1 I Index...
Страница 972: ...I 4 AC Servomotors Servo Drives 1S series with Built in EtherCAT Communications User s Manual I586 Appendices...
Страница 973: ......