SIEPCYEUOQ2V01A Q2V Technical Manual
697
■
o1-05: LCD Contrast Adjustment
No.
(Hex.)
Name
Description
Default
(Range)
o1-05
(0504)
RUN
LCD Contrast Adjustment
Sets the contrast of the LCD display on the keypad.
5
(0 - 10)
When you decrease the setting value, the contrast of the LCD display decreases. When you increase the setting
value, the contrast increases.
■
o1-10: FrqDisplay Max Value
No.
(Hex.)
Name
Description
Default
(Range)
o1-10
(0520)
FrqDisplay Max Value
Sets the value that the drive shows as the maximum output frequency.
Determined by o1-03
(1 - 60000)
To display a maximum output frequency of 100.00, set parameters to these values:
•
o1-10 = 10000
•
o1-11 = 2 [FrqDisplay Decimal Places = (XXX.XX) 2 Decimal Places]
Note:
Set
o1-03 = 3 [FrqDisplay Unit Selection = User-selected units]
before you set
o1-10
and
o1-11
.
■
o1-11: FrqDisplay Decimal Places
No.
(Hex.)
Name
Description
Default
(Range)
o1-11
(0521)
FrqDisplay Decimal Places
Sets the number of decimal places for frequency reference and monitor values.
Determined by o1-03
(0 - 3)
0 : (XXXXX) No Decimal Places
1 : (XXXX.X) 1 Decimal Place
2 : (XXX.XX) 2 Decimal Places
3 : (XX.XXX) 3 Decimal Places
Note:
Set
o1-03 = 3 [FrqDisplay Unit Selection = User-selected units]
before you set
o1-10 [FrqDisplay Max Value]
and
o1-11
.
■
o1-24 to o1-35: Cust.Monitor 1 to 12
No.
(Hex.)
Name
Description
Default
(Range)
o1-24 to o1-35:
(11AD - 11B8)
RUN
Cust.Monitor 1 to 12
Sets a maximum of 12 monitors as user monitors. This parameter is only available when using an
LCD keypad.
o1-24: 101
o1-25: 102
o1-26: 103
o1-27 to o1-35: 0
(0, 101 - 999)
These parameters save the monitor items selected by the LCD keypad [Custom Monitor].
Note:
•
You can show a maximum of three selected monitors on one LCD keypad screen.
–
When you select only one monitor, the text size of this monitor increases. For example, when
o1-25 to o1-35 = 0
, the text size of the
monitor saved in o1-24 increases.
–
When you select two monitors, the text size of these monitors increase.
–
When you select four or more monitors, the fourth monitor and all additional monitors are shown on the next screens.
•
Monitors selected with
o1-24
to
o1-26
can be displayed as a bar graph, analog gauge, or trend plot.
–
Bar graph display: 3 monitors maximum
Select with
o1-24
,
o1-25
, and
o1-26
.
–
Analog gauge display: 1 monitor
Select with
o1-24
.
–
Trend plot display: 2 monitors
Select with
o1-24
and
o1-25
.
•
You can only set parameters
o1-24
to
o1-26
with analog output monitors.
•
You can set all monitors to parameters
o1-27
to
o1-35
.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание Q2V Series
Страница 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Страница 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 143: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 143 EU Declaration of Conformity...
Страница 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Страница 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...
Страница 733: ...SIEPCYEUOQ2V01A Q2V Technical Manual 733...