SIEPCYEUOQ2V01A Q2V Technical Manual
573
■
C: MultSpd Ref3
Setting Value
Function
Description
C
MultSpd Ref3
Uses speed references
d1-01 to d1-16
to set a multi-step speed reference.
Note:
Refer to
“
Setting Procedures for Multi-step Speed Operation
”
in
for more information.
■
D: MultSpd Ref4
Setting Value
Function
Description
D
MultSpd Ref4
Uses speed references
d1-01 to d1-16
to set a multi-step speed reference.
Note:
Refer to "Setting Procedures for Multi-step Speed Operation
”
in
for more information.
■
E: Offset Frq 1
Setting Value
Function
Description
E
Offset Frq 1
Sets the function to add the offset frequency set in
d7-01 [Offset Frq 1]
to the frequency reference when the terminal activates.
Note:
Refer to
“
d7: OFFSET FREQUENCY on page 522
”
for more information.
■
F: Offset Frq 2
Setting Value
Function
Description
F
Offset Frq 2
Sets the function to add the offset frequency set in
d7-02 [Offset Frq 2]
to the frequency reference when the terminal activates.
Note:
Refer to
“
d7: OFFSET FREQUENCY on page 522
”
for more information.
■
10: Offset Frq 3
Setting Value
Function
Description
10
Offset Frq 3
Sets the function to add the offset frequency set in
d7-03 [Offset Frq 3]
to the frequency reference when the terminal activates.
Note:
Refer to
“
d7: OFFSET FREQUENCY on page 522
”
for more information.
■
11: LOC/REM Sel.
Setting Value
Function
Description
11
LOC/REM Sel.
Sets drive control for the keypad (LOCAL) or an external source (REMOTE).
Note:
•
When the MFDI terminal sets the LOCAL/REMOTE selection,
on the keypad is disabled.
•
When LOCAL Mode is selected, the green light for
comes on.
•
When the Run command is ON, you cannot switch between LOCAL Mode and REMOTE Mode.
ON : LOCAL
The keypad is the Frequency reference source and Run command source.
OFF : REMOTE
Parameters
b1-01, b1-02 [Freq. Ref. Sel. 1, Run Comm. Sel 1]
or
b1-15, b1-16 [Freq. Ref. Sel. 2, Run Comm. Sel
2]
set the frequency reference and Run command.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание Q2V Series
Страница 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Страница 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 143: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 143 EU Declaration of Conformity...
Страница 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Страница 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...
Страница 733: ...SIEPCYEUOQ2V01A Q2V Technical Manual 733...