SIEPCYEUOQ2V01A Q2V Technical Manual
337
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
E3-06
(031C)
M2 Base Frequency
Sets the base frequency for the motor 2 V/f pattern.
Determined by E3-01
(0.0 - E3-04)
E3-07
(031D)
M2 Mid A Frequency
Sets a middle output frequency for the motor 2 V/f pattern.
Determined by E3-01
(0.0 - E3-04)
E3-08
(031E)
M2 Mid A Voltage
Sets a middle output voltage for the motor 2 V/f pattern.
Determined by E3-01
(200 V Class: 0.0 - 255.0
V,
400 V Class: 0.0 - 510.0
V)
E3-09
(031F)
M2 Min Out Frequency
Sets the minimum output frequency for the motor 2 V/f pattern.
Determined by E3-01
(0.0 - E3-04)
E3-10
(0320)
M2 Min Out Voltage
Sets the minimum output voltage for the motor 2 V/f pattern.
Determined by E3-01
(200 V Class: 0.0 - 255.0
V,
400 V Class: 0.0 - 510.0
V)
E3-11
(0345)
Expert
M2 Mid B Frequency
Sets a middle output frequency for the motor 2 V/f pattern. Set this parameter to adjust
the V/f pattern for the constant output range. Usually it is not necessary to change this
parameter.
0.0 Hz
(0.0 - E3-04)
E3-12
(0346)
Expert
M2 Min Out Voltage
Sets a middle output voltage for the motor 2 V/f pattern. Set this parameter to adjust the
V/f pattern for the constant output range. Usually it is not necessary to change this
parameter.
0.0 V
(200 V Class: 0.0 to
255.0 V, 400 V Class:
0.0 to 510.0 V)
E3-13
(0347)
Expert
M2 Base Voltage
Sets the base voltage for the motor 2 V/f pattern. Set this parameter to adjust the V/f
pattern for the constant output range. Usually it is not necessary to change this
parameter.
0.0 V
(200 V Class: 0.0 to
255.0 V, 400 V Class:
0.0 to 510.0 V)
◆
E4: MOTOR 2 PARAMETERS
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
E4-01
(0321)
M2 Rated Current (FLA)
Sets the motor rated current for motor 2 in amps.
Determined by o2-04,
C6-01
(10% to 200% of the
drive rated current)
E4-02
(0322)
M2 Rated Slip
Sets the motor rated slip for motor 2.
Determined by o2-04,
C6-01
(0.000 - 20.000 Hz)
E4-03
(0323)
M2 No-Load Current
Sets the no-load current for motor 2 in amps when operating at the rated frequency and
the no-load voltage.
Determined by o2-04,
C6-01
(0 to E4-01)
E4-04
(0324)
M2 Pole Count
Sets the number of poles for motor 2.
4
(2 - 120)
E4-05
(0325)
M2 L-L Resistance
Sets the line-to-line resistance for the motor 2 stator windings.
Determined by o2-04,
C6-01
(0.000 - 65.000 Ω)
E4-06
(0326)
M2 Leak Inductance
Sets the voltage drop from motor 2 leakage inductance as a percentage of Motor Rated
Voltage when motor 2 operates at the rated frequency and rated current.
Determined by o2-04,
C6-01
(0.0 - 60.0%)
E4-07
(0343)
M2 Satur Coeff 1
Sets the motor 2 iron-core saturation coefficient at 50% of the magnetic flux.
0.50
(0.00 - 0.50)
E4-08
(0344)
M2 Satur Coeff 2
Sets the motor 2 iron-core saturation coefficient at 75% of the magnetic flux.
0.75
(E4-07 - 0.75)
E4-09
(033F)
Expert
M2 Mech Loss
Sets the mechanical loss of motor 2. It is set as a percentage of
E4-11 [M2 Rated Power
(kW)]
. Usually it is not necessary to change this setting.
0.0%
(0.0 - 10.0%)
E4-10
(0340)
M2 Iron Loss
Sets the motor iron loss for motor 2.
Determined by o2-04,
C6-01
(0 - 65535 W)
E4-11
(0327)
M2 Rated Power (kW)
Sets the motor rated power in the units from
o1-58 [Mot Capacity Unit]
.
Determined by o2-04,
C6-01
(0.00 - 650.00 kW)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание Q2V Series
Страница 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Страница 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 143: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 143 EU Declaration of Conformity...
Страница 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Страница 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...
Страница 733: ...SIEPCYEUOQ2V01A Q2V Technical Manual 733...