8-54
8-6 Extended Parameters
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8
Parameters Details
Explanation of Set Values
Select the signal read cycle for the pulse prohibition input signal (IPG).
The signal status is updated when the signal status in each signal read cycle that has been set
matches multiple times.
You can lower the possibility of incorrect operation caused by noise by extending the signal read
cycle. However, the responsiveness to signal inputs will be reduced.
Explanation of Set Values
Select the setting unit of Positioning Completion Range 1 and 2 (Pn431 and Pn442), and Error
Counter Overflow Level (Pn014).
Pn519
Command Pulse Prohibition Input Read Setting
Setting
range
0 to 3
Unit
−
Default
setting
Power OFF
and ON
−
Position
Full closing
Set
value
Explanation
0
0.166 ms
1
0.333 ms
2
1 ms
3
1.666 ms
4
0.166 ms (No judgment of multiple matches)
Pn520
Position Setting Unit Selection
Setting
range
0 to 1
Unit
−
Default
setting
Power OFF
and ON
Yes
Position
Full closing
Set
value
Explanation
0
Command unit
1
Encoder unit