8-2 Gain Parameters
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8
Parameters Details
Set the feed-forward amount in torque control. Increasing the set value decreases the position
error and increases the responsiveness. Overshooting, however, will occur more easily.
Set the time constant for the first-order lag filter inserted into the feed forward.
Setting the filter may improve operation if speed overshooting occurs or the noise during operation
is large when the feed forward is set high.
Explanation of Set Values
Select either PI/P operation switching or gain 1/gain 2 switching.
PI/P operation switching is performed using gain switching (GSEL: CN1 pin 27). PI is not changed,
however, if the Torque Limit Selection (Pn521) is set to 3.
For information on switching conditions between gain 1 and gain 2, refer to "6-7 Gain Switching
Function" (P.6-23).
Pn112
Torque Feed-forward Amount
Setting
range
0 to 1,000
Unit
0.1%
Default
setting
Power OFF
and ON
−
Position Speed Full closing
Pn113
Torque Feed-forward Command Filter
Setting
range
0 to 6,400
Unit
0.01 ms
Default
setting
Power OFF
and ON
−
Position Speed Full closing
Pn114
GAIN SWITCHING INPUT OPERATING mode Selection
Setting
range
0 to 1
Unit
−
Default
setting
1
Power OFF
and ON
−
All
Set
value
Explanation
0
Gain 1 (PI/P switching enabled)
1
Gain 1/gain 2 switching available
Gain input
Speed loop operation
COM open
PI operation
COM connected
P operation
Содержание OMNUC G5
Страница 26: ......
Страница 82: ......
Страница 222: ......
Страница 266: ......
Страница 356: ......
Страница 364: ......
Страница 430: ......
Страница 542: ......
Страница 543: ...I OMNUC G5 SERIES AC SERVOMOTOR AND SERVO DRIVE USER S MANUAL Index...
Страница 548: ...Index 5 Index I...
Страница 549: ......