OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8
Parameters Details
Explanation of Set Values
Do not touch the External Regeneration Resistor. A burn injury may result.
Always provide a temperature fuse or other protective measure when using an External
Regeneration Resistor. Regardless of whether the regeneration overload is enabled or disabled,
the Regeneration Resistor can generate heat and may cause burning.
Set this parameter depending on whether the Built-in Regeneration Resistor is used, or the Built-
in Regeneration Resistor is disconnected and an External Regeneration Resistor is connected.
(The External Regeneration Resistor connection terminal is connected.)
To use the Built-in Regeneration Resistor, always set this parameter to 0.
Explanation of Set Values
Pn016
Regeneration Resistor Selection
Setting
range
0 to 3
Unit
−
Default
setting
0
Power OFF
and ON
Yes
All
Set
value
Explanation
0
Regeneration Resistor used: Built-in Resistor
The regeneration processing circuit will operate and the regeneration overload (alarm display
No. 18) will be enabled according to the Built-in Resistor (with approx. 1% duty).
1
Regeneration Resistor used: External Resistor
The regeneration processing circuit will operate, and regeneration overload (alarm display
No. 18) will cause a trip when the operating rate of the Regeneration Resistor exceeds 10%.
2
Regeneration Resistor used: External Resistor
The regeneration processing circuit will operate, but regeneration overload (alarm display
No. 18) will not occur.
3
Regeneration Resistor used: None
The regeneration processing circuit and regeneration overload (alarm display No. 18) will not
operate, and all regenerative energy will be processed by the built-in capacitor.
Pn017
External Regeneration Resistor Setting
Setting
range
0 to 4
Unit
−
Default
setting
Power OFF
and ON
Yes
All
Set
value
Explanation
0
Regeneration load ratio is 100% when operating rate of the External Regeneration Resistor
is 10%.
1
Reserved
2
Reserved
3
Reserved
4
Reserved
Содержание OMNUC G5
Страница 26: ......
Страница 82: ......
Страница 222: ......
Страница 266: ......
Страница 356: ......
Страница 364: ......
Страница 430: ......
Страница 542: ......
Страница 543: ...I OMNUC G5 SERIES AC SERVOMOTOR AND SERVO DRIVE USER S MANUAL Index...
Страница 548: ...Index 5 Index I...
Страница 549: ......