5-2
5-1 Position Control
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
5
BASIC CONTROL Mode
Parameters Requiring Settings
CONTROL mode Selection (Pn001)
Select the position control (Set values: 0, 3 or 4).
Command Pulse Input Process (Pn005, Pn006, Pn007)
Position command input terminals are classified into the input 1 system (+CW, -CW, +CCW, -
CCW) and input 2 system (+CWLD, -CWLD, +CCWLD, -CCWLD).
If the position command output is a line-driver output, set input 1. If it is an open collector
output, set input 2. Although input 2 can also be used for a line-driver output, the allowable
maximum input frequency will become lower than when input 1 is selected.
Parameter
number
Parameter name
Explanation
Reference
Pn001
CONTROL mode Selection
Select the CONTROL mode.
Pn005
Command Pulse Input Selection Select the command pulse input terminal.
Pn006
Command Pulse Rotation
Direction Switching
Selection
Set the count direction for the command pulse input.
Pn007
COMMAND PULSE
mode Selection
Set the count method for the command pulse input.
Pn009
Electronic Gear Ratio
Numerator 1
Set the numerator of the electronic gear ratio for the
command pulse input.
Pn010
Electronic Gear Ratio
Denominator
Set the denominator of the electronic gear ratio for the
command pulse input.
Parameter
number
Parameter name
Explanation
Setting
range
Unit
Pn005
Command Pulse
Input Selection
Select the command pulse input
terminal.
0: Photocoupler input (+CW, -CW,
+CCW, -CCW)
1: Input for line driver only (+CWLD,
-CWLD, +CCWLD, -CCWLD)
0 to 1
−
Pn006
Command Pulse
Rotation Direction
Switching
Selection
Set the count direction for the
command pulse input.
0: Command pulse, forward
direction
1: Command pulse, reverse
direction
0 to 1
−
Pn007
COMMAND
PULSE mode
Selection
Set the count method for the
command pulse input.
0: 90 phase difference (A/B) signal
input)
1: Forward/reverse pulse
2: 90 phase difference (A/B) signal
input)
3: Feed pulse/direction signal
0 to 3
−
Содержание OMNUC G5
Страница 26: ......
Страница 82: ......
Страница 222: ......
Страница 266: ......
Страница 356: ......
Страница 364: ......
Страница 430: ......
Страница 542: ......
Страница 543: ...I OMNUC G5 SERIES AC SERVOMOTOR AND SERVO DRIVE USER S MANUAL Index...
Страница 548: ...Index 5 Index I...
Страница 549: ......