4-35
4-3 Wiring Conforming to EMC Directives
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
4
System Design
Selecting Other Parts for Noise Resistance
This section explains the criteria for selecting the connection components required to improve
noise resistance.
Understand each component's characteristics, such as its capacity, performance, and
applicable range when selecting the connection components.
For more details, contact the manufacturers directly.
Noise Filters for Motor Output
Use noise filters without built-in capacitors on the motor output lines.
Select a noise filter with a rated current at least twice the driver's continuous output current.
The following table shows the noise filters that are recommended for motor output lines.
Note 1. Motor output lines cannot use the same noise filters for power supplies.
Note 2. General noise filters are made for power supply frequencies of 50/60 Hz. If these noise filters are
connected to the PWM output of the driver, a very large (about 100 times larger) leakage current
will flow through the noise filter's capacitor and the driver could be damaged.
External Dimensions
3G3AX-NF001/-NF002
Manufacturer
Model
Rated
current
Comment
OMRON
3G3AX-NF001
6 A
For inverter output
3G3AX-NF002
12 A
3G3AX-NF003
25 A
3G3AX-NF004
50 A
3G3AX-NF005
75 A
3G3AX-NF006
100 A
4
−
M
M4
C
B
A
P
E
F
J
H
G
Model
Dimensions (mm)
A
B
C
E
F
G
H
J
M
P
3G3AX-NF001
140
125
110
70
95
22
50
20
4.5
dia.
156
3G3AX-NF002
160
145
130
80
110
30
70
25
5.5
dia.
176
Содержание OMNUC G5
Страница 26: ......
Страница 82: ......
Страница 222: ......
Страница 266: ......
Страница 356: ......
Страница 364: ......
Страница 430: ......
Страница 542: ......
Страница 543: ...I OMNUC G5 SERIES AC SERVOMOTOR AND SERVO DRIVE USER S MANUAL Index...
Страница 548: ...Index 5 Index I...
Страница 549: ......