4-1
4-1 Installation Conditions
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
4
System Design
4-1 Installation Conditions
Servo Drive Installation Conditions
Dimension Conditions around Equipment
Install drivers according to the dimensions shown in the following illustration to ensure proper heat
dispersion inside the driver and convection inside the panel. If the drivers are installed side by
side, install a fan for air circulation to prevent uneven temperatures inside the panel.
Mounting Direction
Mount the drivers in a direction (perpendicular) so that the model number can be seen properly.
Environment Operating Conditions
The environment in which drivers are operated must meet the following conditions. Drivers may
malfunction if operated under any other conditions.
Operating ambient temperature: 0 to
+
55
°
C (Take into account temperature rises in the
following individual drivers themselves.)
Operating humidity: 90% RH max. (with no condensation)
Operating atmosphere: No corrosive gases.
Altitude: 1,000 m max.
Derating must be applied for higher altitudes.
Ambient Temperature Control
To operate in environments in which there is minimal temperature rise is recommended to
maintain a high level of reliability.
When the driver is installed in a closed space, such as a box, ambient temperature will rise due
to temperature rise in each unit. Use a fan or air conditioner to prevent the driver's ambient
temperature from exceeding 55
°
C.
Driver surface temperatures may rise to as much as 30
°
C above the ambient temperature. Use
heat-resistant materials for wiring, and keep its distance from any devices or wiring that are
sensitive to heat.
The limit of a driver is largely determined by the ambient temperature around the internal
electrolytic capacitors. When an electrolytic capacitor reaches its limit, electrostatic capacity drops
and internal resistance increases. This leads to overvoltage alarms, malfunctioning due to noise,
and damage to individual elements.
Driver
Driver
Driver
Side
W
40 mm or more
W
100 mm or more
100 mm or more
Air
Air
Fan
Fan
W = 10 mm or more
Содержание OMNUC G5
Страница 26: ......
Страница 82: ......
Страница 222: ......
Страница 266: ......
Страница 356: ......
Страница 364: ......
Страница 430: ......
Страница 542: ......
Страница 543: ...I OMNUC G5 SERIES AC SERVOMOTOR AND SERVO DRIVE USER S MANUAL Index...
Страница 548: ...Index 5 Index I...
Страница 549: ......