3-27
3-1 Servo Drive Specifications
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
3
Specifications
Monitor Connector Specifications (CN5)
Monitor Output Signals List
Monitor output (CN5)
Connectors for CN5 (6 pins)
Monitor output circuit
Pin
Number
Symbol
Name
Function and interface
1
AM1
Analog monitor output 1
Outputs the analog signal for the monitor.
Default setting: Motor rotation speed 1 V/(1,000 r/min)
You can use Pn416 and Pn417 to change the item and
unit.
You can use Pn421 to change the output method.
2
AM2
Analog monitor output 2
Outputs the analog signal for the monitor.
Default setting: Motor rotation speed 1 V/(1,000 r/min)
You can use Pn418 and Pn419 to change the item and
unit.
You can use Pn421 to change the output method.
3
GND
Analog monitor ground
Ground for analog monitors 1, 2
4
Not used
Do not connect.
5
Not used
Do not connect.
6
Not used
Do not connect.
Name
Model
Manufacturer
Connector housing
51004-0600
Molex Japan
Connector terminal
50011-8000
Molex Japan
Servo Drive
Monitor equipment
3 GND
1/2 AM1/AM2
1 k
Ω
+
−
Содержание OMNUC G5 R88D-KN series
Страница 22: ......
Страница 164: ......
Страница 228: ......
Страница 274: ......
Страница 342: ......
Страница 392: ......
Страница 432: ......
Страница 450: ......
Страница 451: ...I OMNUC G5 Series AC Servo Drives Users Manual Built in MECHATROLINK II communications type Index ...
Страница 456: ......
Страница 457: ......