![Omron NYP17-*-11 SERIES Скачать руководство пользователя страница 174](http://html.mh-extra.com/html/omron/nyp17-11-series/nyp17-11-series_user-manual_744507174.webp)
Additional Information
• The default
Input sensitivity setting
is
Standard voltage sensitivity
and this is correct.
Do not set this parameter to
Low voltage sensitivity
. Doing so can cause a system malfunc-
tion when switching to battery mode.
• The UPS Setting Utility can not be used when the Power Attendant Lite Utility is active.
To use the UPS Setting Utility:
(1) Right-click the Power Attendant Lite Utility icon and select Agent Stop.
(2) Use the UPS Setting Utility.
(3) Right-click the Power Attendant Lite Utility icon and select Agent Start.
5-8-2
Connect UPS Using the I/O Connector
The I/O connector of the Industrial Panel PC:
• receives the power status of the UPS with the UPS Mode Input when the Panel PC has a Windows
operating system. For other operating systems this input is not functional.
• indicates the power status of the Panel PC to the UPS with the Power Status Output.
Additional Information
• A UPS connection using the I/O connector is only possible for a Panel PC with a Windows
operating system. For all other operating systems use the USB connector to connect the
UPS.
Refer to
5-8-1 Connect UPS Using the USB Connector
• The Panel PC does not react automatically to the UPS Mode Input.
A custom software program is required
to shut down the Panel PC when needed.
UPS Drivers and the required software is available.
• For Panel PCs with Windows 10 or Windows 7 preinstalled:
• Drivers for the S8BA UPS are pre-installed
• Installation files and manual for the UPS Settings Utility are availabe in the installer directory
D:\OMRON-NY\Installers\UPS Settings Utility
• For all other Panel PCs following software can be downloaded from the OMRON download site:
• Drivers for the S8BA UPS
• Installation files and manual for the UPS Settings Utility (Windows only)
Precautions for Safe Use
• Always use the recommended uninterruptible power supply (UPS) to prevent data loss and
other system file integrity issues caused by unexpected power interruption.
• Use an Omron S8BA UPS with the correct revision number to prevent improper system shut-
down.
• Correctly perform wiring and setting, and ensure that the shutdown by the UPS can be exe-
cuted.
Follow the steps below to connect the S8BA UPS to the I/O connector of the Panel PC and to config-
ure it correctly.
Refer to
on page 5 - 37 for I/O Connector details.
1
Ensure the revision number of the UPS is correct.
Refer to
on page 2 - 23 for more information.
5 Installation
5 - 54
NY-series Industrial Panel PC User's Manual (W555)
Содержание NYP17-*-11 SERIES
Страница 32: ...Sections in this Manual 30 NY series Industrial Panel PC User s Manual W555 ...
Страница 40: ...1 Overview 1 8 NY series Industrial Panel PC User s Manual W555 ...
Страница 64: ...2 Hardware 2 24 NY series Industrial Panel PC User s Manual W555 ...
Страница 182: ...5 Installation 5 62 NY series Industrial Panel PC User s Manual W555 ...
Страница 236: ...7 Maintenance 7 46 NY series Industrial Panel PC User s Manual W555 ...
Страница 258: ...Appendices A 22 NY series Industrial Panel PC User s Manual W555 ...
Страница 259: ...I Index I 1 NY series Industrial Panel PC User s Manual W555 I ...
Страница 262: ......
Страница 263: ......