1-11
Operation Commands (CompoWay/F Communications)
Section 1-7
Co
m
p
o
W
a
y
/F
Co
m
m
u
n
ica
tio
n
s
1-7
Operation Commands (CompoWay/F Communications)
Operation commands are sent using the following FINS-mini command text
format.
Command
FINS-mini Command Text
Operation commands for the K3HB are shown in the following table.
Note
A software reset will not respond (no service PDU response).
Response
FINS-mini Response Text
Response Codes
Data name
Explanation
MRC/SRC
Specify the FINS-mini operation command.
Operation code
Specify an operation code.
Related information
Specify information related to the command.
Operation code
Description
Related information
00
Write via communications
00: OFF (Disabled)
01: ON (Enabled)
01
Reset
00
02
Bank selection
00 to 07: Bank 0 to 7
03
Zero execute/cancel
00: Zero cancel
01: Zero execute
06
Software reset
00
07
Move to setting area 1
00
08
Move to protect level
00
0B
Initialize settings
00
"30"
"05"
Instruction
code
Related
information
SRC
MRC
2
2
2
2
Data name
Explanation
MRC/SRC
FINS-mini command text appears here.
Response code
Result of execution of the command.
Response
code
Error name
Explanation
“1001”
Command length too
long
The command is too long.
“1002”
Command length too
short
The command is too short.
“1100”
Parameter error
Operation code or related information is not
correct.
"30"
"05"
Response code
(MRES/SRES)
SRC
MRC
2
2
4
Содержание K3HB
Страница 2: ...K3HB Digital Indicators Communications User s Manual Revised March 2005...
Страница 3: ...iv...
Страница 15: ...xvi...
Страница 19: ...xx...
Страница 21: ...Part 1 CompoWay F...
Страница 69: ...Part 2 DeviceNet...
Страница 95: ...6 10 Ladder Programming Examples Section 4 3 Remote I O Com munications...
Страница 103: ...7 8 Explicit Messages Specific to DeviceNet compatible Digital Indicators Section 5 3 Explicit Message Communications...
Страница 111: ...8 8 Message Communications Performance Section 6 2 Communications Performance...
Страница 127: ...Part 3 BCD Output...
Страница 147: ......