Functions and Oper
ations
5.23 Holding Maximum and Minimum Values
5-65
5.23 Holding Maximum and Minimum Values
• Each time the
[MAX/MIN] Key is pressed in the RUN level, the
maximum or minimum value recorded while a measurement is
being performed will be displayed.
●
Switching Maximum and Minimum Value Displays
Each time the
[MAX/MIN] Key is pressed in the RUN level, the PV display switches as follows: present
value
→
maximum value
→
minimum value
→
present value.
●
Resetting the Maximum and Minimum Values
The maximum and minimum values can be reset by a RESET input or
by pressing the
[MAX/MIN] Key for 1 s.
R P
C
Initializing
Measuring
Max. value
Min. value
Measurement status
Power supply
Initializing
Measuring
Measurement value
Measuring
Measurement stopped
90000
Max
1234
.
5
90000
3012
.
6
90000
985
.
7
Min
MIN value
MAX value
Present value
CMW
Hold
CMW
Hold
CMW
Hold