background image

Automatic Blood Pressure Monitor

with Arm Cuff

Model

HEM-711AC

INSTRUCTION MANUAL

ESP

AÑOL

ENGLISH 

280239_HEM-7011-E_S.qxd  2/19/08  3:00 PM  Page 1

Содержание INTELLI SENSE HEM-711AC

Страница 1: ...Automatic Blood Pressure Monitor with Arm Cuff Model HEM 711AC INSTRUCTION MANUAL ESPAÑOL ENGLISH ...

Страница 2: ...ge Value Symbol 10 Heartbeat Symbol Hypertension Indicator 12 Battery Installation 13 Using the AC Adapter 15 Setting the Date and Time 17 Applying the Arm Cuff 21 Taking a Measurement 24 Special Conditions 27 Using the Memory Function 28 Averaging Function 28 To Display the Measurement Values 28 To Delete All Values Stored in the Memory 30 Care and Maintenance Care and Maintenance 31 Error Indica...

Страница 3: ...ic method of blood pressure measurement This means the monitor detects your blood s movement through your brachial artery and converts the movements into a digital reading The monitor stores measurement results The HEM 711AC comes with the following components Monitor Standard Adult Arm Cuff AC Adapter Storage Case Warranty Card Instruction Manual printed in English and Spanish The HEM 711AC Intel...

Страница 4: ...r other property OPERATING THE DEVICE Contact your physician for specific information about your blood pressure Self diagnosis and treatment using measured results may be dangerous Follow the instructions of your physician or licensed healthcare provider If battery fluid gets in your eyes immediately rinse with plenty of clean water Contact a physician immediately Read all of the information in th...

Страница 5: ...icable local regulations Unlawful disposal may cause environmental pollution Do not use a cellular phone near the device It may result in an operational failure Use only Omron authorized parts and accessories Parts and accessories not approved for use with the device may damage the unit Use only 1 5V manganese or alkaline batteries with this device Do not use other types of batteries This may dama...

Страница 6: ...e floor Do not submerge the device or any of the components in water Store the device and the components in a clean safe location Changes or modification not approved by Omron Healthcare will void the user warranty Do not disassemble or attempt to repair the unit or components SAFETY INFORMATION 6 ...

Страница 7: ...loor Rest your arm on a table so that the cuff is at the same level as your heart 6 Remain still and do not talk during the measurement 7 Keep a record of your blood pressure and pulse readings for your physician A single measurement does not provide an accurate indication of your true blood pressure You need to take and record several readings over a period of time Try to measure your blood press...

Страница 8: ...ton Date Time Setting Button Display AC Adapter Jack Components Air Tube Air Plug Connects to Air Jack Arm Cuff Storage Case AC Adapter KNOW YOUR UNIT INSTRUCTION MANUAL ESP ESPAÑOL ENGLISH Automatic Blood Pressure Monitor with Arm Cuff Model HEM 711AC Instruction Manual ...

Страница 9: ...od Pressure Systolic Blood Pressure Memory Symbol Pulse Display Date Time Display Low Battery Indicator Average Value Symbol Heartbeat Symbol Hypertension Indicator Deflation Symbol Irregular Heartbeat Symbol Movement Error Symbol ...

Страница 10: ...re If the irregular heartbeat symbol displays with your measurement results we recommend you consult your physician Follow the directions of your doctor MOVEMENT ERROR SYMBOL The Movement Error Symbol is displayed if you move your body during the measurement Please remove the arm cuff wait 2 3 minutes reapply the arm cuff then take another measurement AVERAGE VALUE SYMBOL The Average Value Symbol ...

Страница 11: ...nd morbidity The AHA recommends a lower home blood pressure goal for certain patients including diabetic patients pregnant women and patients with renal failure1 The monitor is not intended to be a diagnostic device WARNING Contact your physician for specific information about your blood pressure Self diagnosis and treatment using measured results may be dangerous Follow the instructions of your p...

Страница 12: ...pulse rate if the reading is above 135 for the Systolic Blood Pressure value and or 85 for the Diastolic Blood Pressure value USING THE MEMORY FUNCTION The Heartbeat Symbol flashes when the blood pressure reading stored in the memory is above 135 for the Systolic Blood Pressure value and or 85 for the Diastolic Blood Pressure value Omron Healthcare recommends you contact your physician if the HEAR...

Страница 13: ...and slide the cover off in the direction of the arrow 2 Install 4 AA size batteries so the positive and negative polarities match the polarities of the battery compartment as indicated 3 Replace the battery cover BATTERY INSTALLATION Battery Cover ...

Страница 14: ... off before replacing the batteries If the batteries are removed while the unit is still on the date and time will be reset to that of the previous use However the measurement results are not deleted When the batteries are replaced you may need to reset the date and time If the year is flashing on the display screen refer to Resetting the Date and Time on page 20 CAUTION Dispose of the device comp...

Страница 15: ...the AC Adapter is used If no batteries are installed you may need to reset the date and time if the AC Adapter is disconnected The measurement results will not be deleted CAUTION Use only Omron authorized parts and accessories Parts and accessories not approved for use with the device may damage the unit USING THE AC ADAPTER ...

Страница 16: ... THE AC ADAPTER Hold and pull the Housing to remove the AC Adapter from the electrical outlet Do not remove by pulling on the cord Remove the AC Adapter plug from the monitor WARNING Do not plug or unplug the power cord into the electrical outlet with wet hands CAUTION Do not overload power outlets Plug the device into the appropriate voltage outlet USING THE AC ADAPTER 1 2 16 Housing Cord ...

Страница 17: ...and times The monitor can also calculate an average reading based on the three most recent measurements taken within 10 minutes of the last reading NOTES If only two readings are stored in the memory for the 10 minute period the average is based on the two readings If one reading is stored in the memory for the 10 minute period this reading is displayed as the average 1 TO START THE SETTING Press ...

Страница 18: ...rements of one year Press the Date Time Setting button to set the current year The month flashes on the display NOTE Press and hold the MEMORY button to advance the date and time values faster 3 SETTING THE MONTH Press the MEMORY button to advance by increments of one month Press the Date Time Setting button to set the current month The day flashes on the display 18 STOP STOP STOP ...

Страница 19: ...e by increments of one hour Press the Date Time Setting button to set the current hour The minute flashes on the display 6 SETTING THE MINUTE Press the MEMORY button to advance by increments of one minute Press the Date Time Setting button to set the minute setting 7 TO TURN THE MONITOR OFF Press the START STOP button NOTE The monitor will automatically turn off after the minute has been set after...

Страница 20: ...ith the monitor in the off position 1 Press and hold the Date Time Setting button The year flashes on the display 2 Follow the instruction from step 2 on page 18 NOTE If you need to change the Date and Time always adjust the Date and Time setting before taking the next measurement SETTING THE DATE AND TIME 20 STOP ...

Страница 21: ...ce is intended for use in measuring blood pressure and pulse rate in the adult population Do not use this device on infants or persons who cannot express their intentions APPLYING THE CUFF ON THE LEFT ARM 1 Make sure the air plug is securely inserted in the main unit 2 Remove tight fitting clothing from your upper left arm APPLYING THE ARM CUFF ...

Страница 22: ...our arm and aligned with your middle finger The air tube runs down the inside of your arm The bottom of the cuff should be approximately 1 2 above your elbow 4 Wrap the cuff firmly in place around your arm using the closure strip APPLYING THE ARM CUFF 22 1 2 inch 1 2 cm Air Tube Blue Arrow ...

Страница 23: ...is instruction for Step 4 on page 22 Apply the cuff to your right upper arm so the blue arrow and the air tube runs along the inside of your elbow The bottom of the cuff should be approximately 1 2 above your elbow NOTE Be careful not to rest your arm on the air tube This will restrict the flow of air to the cuff ...

Страница 24: ...e necessary the monitor automatically re inflates the cuff up to 30 mmHg higher than the initial inflation and restarts the measurement CAUTION Operate the device only as intended Do not use the device for any other purpose 1 Sit on a chair with your feet flat on the floor Place your left arm on a table so the cuff is level with your heart ...

Страница 25: ...lation Do not move your arm and remain still until the entire measurement process is completed NOTE To stop the inflation or measurement press the START STOP button The monitor will stop inflating start deflating and turn off 3 Inflation stops automatically and the measurement is started As the cuff deflates decreasing numbers appear on the display The Heartbeat Symbol flashes at every heartbeat T...

Страница 26: ...he START STOP button to turn the monitor off NOTE The monitor will automatically turn off after five minutes When the measurement is complete the Heartbeat Symbol flashes on the display with your blood pressure and pulse rate if the reading is above 135 for the Systolic Blood Pressure value and or 85 for the Diastolic Blood Pressure value START STOP ...

Страница 27: ...is known to be more than 220 mmHg press and hold the START STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure NOTES Do not apply more pressure than necessary The monitor will not inflate above 299 mmHg When the measurement is complete the arm cuff completely deflates Your blood pressure and pulse rate are displayed START STOP ...

Страница 28: ...TION The monitor calculates the average reading based on the three most recent sets of measurement values taken within 10 minutes of the most recent reading NOTE If two sets of measurement values are stored in the memory for the 10 minutes period the average is based on the two sets of measurement value If one set of measurement values is stored this is displayed as the average TO DISPLAY THE MEAS...

Страница 29: ... values are displayed from the most recent to the oldest NOTES The date and time are alternately displayed with the measurement values Press the MEMORY button to display the next set of values Press and hold the MEMORY button to display the values faster 3 Press the START STOP button to turn the power off Alternating display ...

Страница 30: ...values stored in the memory All values will be deleted 1 First press the MEMORY button While holding it down press the START STOP button together for more than 2 seconds All values will be deleted 2 Press the START STOP button to turn the monitor off NOTE The monitor will automatically turn off after 5 minutes START STOP ...

Страница 31: ...rd Do not forcefully bend the arm cuff or air tube Do not fold tightly Clean the monitor with a soft dry cloth Do not use any abrasive or volatile cleaners Do not attempt to clean the cuff CAUTION Do not submerge the device or any of the components in water Do not subject the monitor to extreme hot or cold temperatures humidity or direct sunlight CAUTION Store the device and the components in a cl...

Страница 32: ...ime Use the unit consistent with the instruction provided in this manual CAUTION Changes or modification not approved by Omron Healthcare will void the user warranty Do not disassemble or attempt to repair the unit or components CAUTION Use only Omron authorized parts and accessories Parts and accessories not approved for use with the device may damage the unit ...

Страница 33: ...arm cuff and take another measurement Cuff over inflated Take another measurement and remain still until the measurement is complete Monitor could not detect pulse wave Air plug is not connected Batteries are worn Replace the four batteries Refer to Battery Installation ERROR INDICATORS 33 ERROR INDICATORS ANDTROUBLESHOOTINGTIPS ...

Страница 34: ...es Check the battery installation for proper placement of the battery polarities Measurement values appear too high or too low Blood pressure varies constantly Many factors including stress time of day and how you wrap the cuff may affect your blood pressure Review the sections Before Taking a Measurement and Taking a Measurement TROUBLESHOOTING TIPS ...

Страница 35: ...ne or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the product and the receiver Connect the product into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does no...

Страница 36: ...isit our website at www omronhealthcare com Enclose the Proof of Purchase Include 5 00 for the return shipping and handling Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in transit Because of possible loss in transit we recommend insuring the product with return receipt requested ALL IMPLIED WARRANTIES INCL...

Страница 37: ...hen used 2 times a day with 4 new alkaline batteries Operating Temperature 50ºF to 104ºF 10ºC to 40ºC 30 to 85 RH Humidity Storage Temperature 4ºF to 140ºF 20ºC to 60ºC 10 to 95 RH Humidity Air Pressure 700 1060 hPa Main Unit Weight Approximately 12 1 2 oz 355 g not including batteries Main Unit Dimensions Approx 6 3 32 l 5 5 32 w 3 5 16 h 155 mm 131 mm 84 mm Cuff Size Approx 5 3 4 w 17 1 2 l 146 ...

Страница 38: ...Manufactured by OMRON HEALTHCARE Made in China Distributed by OMRON HEALTHCARE INC 1200 Lakeside Drive Bannockburn Illinois 60015 www omronhealthcare com Copyright 2008 Omron Healthcare Inc ...

Отзывы: