WARNING
The Power Supply Box, charging contacts on both the Docking Target and the AMR,
and the drive wheel motors can get hot during operation. Allow these items to cool
down prior to servicing.
Precautions for Safe Use
• In case of fire, use a type ABC or type BC dry chemical fire extinguisher.
• Never access the interior of the AMR while it is connected to the Docking Target.
• Avoid liquid near the Charging Station and the AMR.
Precautions for Correct Use
• Always ship and store the AMR, Power Supply Box, and the Docking Target in an upright po-
sition in a clean and dry area. Do not lay the shipping crates on their sides or any other non-
upright position. This could damage the Power Supply Box and the Docking Target.
• You must route and secure the power cords properly. They must be secured in such a way
that prevents straining of the connection points.
The following safety measures associated with high power transfer are described below.
• When the Power Supply Box main disconnect switch is ON, the electrical access panel door locks
automatically to prevents access.
• The door on the Power Supply box can only be accessed with a key to prevent unauthorized access
to the main electrical compartment.
• When the Docking Target detects an AMR or external battery, a series of interlocking checks are
performed to confirm that all devices are in an operational state before charging will begin.
The Power Supply Box uses a 4 meter long power cord (25.4 mm diameter) to transfer power to the
Docking Target.
Power Supply Box
The Power Supply Box has LED indicators to display the status of the unit as described below. A Serv-
ice button is also present for use when connecting a fully depleted battery.
The Power Supply Box has a main disconnect switch that turns the unit ON or OFF. When the main
disconnect switch is placed in the vertical position (ON position), the unit powers ON and illuminates
all LEDs on the front panel of the Power Supply Box for 2 seconds. The Power Supply Box is opera-
tional at this moment. Use the LEDs determine the operational status of the Power Supply Box. Plac-
ing the main disconnect switch in the horizontal position (OFF position) will remove power from the
Power Supply Box.
The Power Supply Box performs several diagnostic tests. If a problem is detected, the Power Supply
Box enters a safe state in which all charging power turned OFF and the red LED flashes. Refer to
5-4-2 Battery Charging Problems
on page 5-6 for more information.
The Power Supply Box will not automatically charge a battery if it is absolutely depleted.
Pressing the Service button on the Power Supply Box during a charging session will interrupt charg-
ing. Disconnect the battery and then reconnect to resume charging.
4 Operation
4-22
HD-1500 Platform User's Manual (I645)
Содержание HD-1500 Platform
Страница 1: ...HD 1500 Platform User s Manual I645 E 03 ...
Страница 6: ...Manual Information 4 HD 1500 Platform User s Manual I645 ...
Страница 38: ...Revision History 36 HD 1500 Platform User s Manual I645 ...
Страница 206: ...5 Troubleshooting 5 14 HD 1500 Platform User s Manual I645 ...
Страница 236: ...6 Maintenance 6 30 HD 1500 Platform User s Manual I645 ...
Страница 250: ...Appendices A 14 HD 1500 Platform User s Manual I645 ...
Страница 251: ...I Index I 1 HD 1500 Platform User s Manual I645 I ...
Страница 254: ...Index I 4 HD 1500 Platform User s Manual I645 ...
Страница 255: ......