background image

8

In the interest of product improvement, specifications are subject to change without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. L095-E1-02

OMRON Corporation

Industrial Automation Company

Industrial Devices and Components Division H.Q.
Industrial Control Components Department

Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7119/Fax: (81)75-344-7149

Printed in Japan
1204-1.3C (0298) (M)

Warranty and Application Considerations

Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or 
other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, 
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER 
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET 
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR 
IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, 
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON 
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE 
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, 
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE 
MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of 
products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will 
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT 
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON 
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR 
SYSTEM.

Disclaimers

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with 
your OMRON representative at any time to confirm actual specifications of purchased product.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

Содержание H3AM

Страница 1: ...ilt in instantaneous contact NS Memory retention NSR Finger protection terminal block Enables easy sequence checks through instantaneous outputs for a zero set value at any time range Model Number Legend Ordering Information List of Models Note The operation of the instantaneous contacts differs for the self resetting and electric resetting systems Refer to Timing Charts on page 5 for details H3AM...

Страница 2: ...onforms to EN61812 1 IEC60664 1 4 kV 2 VDE0106 P100 Output category according to IEC60947 5 1 Model Full scale on dial Set time unit s 10 s min 10 min h hour 10 h hour H3AM A 3 0 5 to 30 s 0 05 to 3 min 0 5 to 30 min 0 05 to 3 h 0 5 to 30 h H3AM B 6 1 to 60 s 0 1 to 6 min 1 to 60 min 0 1 to 6 h 1 to 60 h H3AM C 12 0 2 to12 s 2 to 120 s 0 2 to 12 min 2 to 120 min 0 2 to 12 h Rated supply voltage 10...

Страница 3: ...inals square wave noise by a noise simulator pulse width 100 ns 1 µs 1 ns rise Static immunity Malfunction 8 kV Destruction 15 kV Vibration resistance Destruction 10 to 55 Hz 0 75 mm single amplitude for 2 cycles each in 3 directions 8 min per cycle Malfunction 10 to 55 Hz 0 5 mm single amplitude for 2 cycles each in 3 directions 8 min per cycle Shock resistance Destruction 300 m s2 3 times each i...

Страница 4: ...r Instantaneous or Time limit Output Selector for R2 Relay only for H3AM NS models Default setting is time limit output Time Unit Selector Illustrated Model H3AM C Note The scale goes up to 3 with the H3AM A and up to 6 with the H3AM B Model Applicable time unit Full scale on dial s 10 s min 10 min h 10 h H3AM A H3AM B H3AM C 3 6 12 No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes...

Страница 5: ... contact NO 6 8 Power indicator POWER Output indicator UP Reset 9 10 t t t t Rt Rt Note 1 The R2 contacts 7 8 and 6 8 are programmable and can be set to either instantaneous or time limit contacts using the switch located on the bottom of the Timer 2 Rt is the reset time and t is the set time Note t is the set time Rt is the reset application time and t is the power interruption time H3AM NS H3AM ...

Страница 6: ... 27 5 dia Four 5 dia holes Mounting Holes 70 0 4 96 81 dia hole Note Tightening torque for panel mounting is as follows 300 m N m 50 m N m Y92S 35 Note Use Waterproof Packing to provide a level of water protection that complies with IP65 standards Depending on the operating environment the Waterproof Packing may deteriorate contract or harden and so regular replacement is recommended 1 2 3 4 5 6 7...

Страница 7: ... malfunction or outputs may be unstable Precautions for Correct Use Changing Switch Settings Be sure to adjust the time unit selector and instantaneous or time limit output selector for R2 relay only before the Timer is turned ON otherwise the Timer may be damaged or malfunction Be sure to set the time only when Timer has stopped otherwise the Timer may malfunction Setting the Operating Time Do no...

Страница 8: ...ANTY NEGLIGENCE OR STRICT LIABILITY In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINAT...

Отзывы: